Altinex MX2414RM User Manual Download Page 9

SWITCHERS

8

IBM PIN No.

MX2416RM

 PIN No.

2

2

3

3

5

5

Connection IBM-PC 9-pin D to 

MX2416RM

 9-pin D

Note: 4, 6, 8 shorted together in IBM side only.

Port setting preferences for the control system or
computer being used to control the switcher should
be set as follows:

BAUD RATE (Bits per second)

2400

Data bits

8

Parity

None

Stop Bits

1

There is no software or hardware flow control
implemented. The RS-232 input has a 6-character
buffer and will not execute additional commands
until the previous command is fully processed.

7.2 RS-232 PROTOCOL

[INP0]

All channels OFF

[INP1]

Select Input 1

[INP2]

Select Input 2

[INP3]

Select Input 3

[INP4]

Select Input 4

[INP5]

Select Input 5

[INP6]

Select Input 6

[RSET]

Reset unit to user defaults

[VERN]

Returns firmware version
numbers

Inputs 5 & 6 are not selectable on the 

MX2414RM

Commands must be issued as shown, in ALL
CAPS and with the brackets [ ] included in the
command string. After processing a valid
command, an [OK] string will be returned. A
command echo will also follow the [OK].

For instance, a command of [INP1] would return
[OK][INP1]. The [VERN] command will return the
corresponding software version being used by the
switcher, such as an error string, [ERR] will be
returned.

If the control system being used is not setup to wait
for the [OK] string, it is important to include a 100
milliseconds delay between each command.

The 

MX2416RM

 Switcher is also designed to send

feedback commands from the switcher to the
control system when the buttons on the front panel
of the switcher are pressed.

The feedback codes are as follows:

Key

pressed

Description

Feedback

Code

1

Input Select

[INP1]

2

Input Select

[INP2]

3

Input Select

[INP3]

4

Input Select

[INP4]

5

Input Select

[INP5]

6

Input Select

[INP6]

STAND BY

All Outputs OFF

[INP0]

RESET

Reset

[RSET][INPx]

Inputs 5 & 6 are not selectable on 

MX2414RM.

The following commands are added to the
standard set of commands in order to facilitate
control of multiple units using a single RS-232
control port. These commands are available on the
switcher that has firmware revision number: 2.0.
Use [VERN] commands to determine the firmware
revision. These commands add additional flexibility
to the switcher.

[InnOmm]

nn 

-

Input Number 00 to 99

mm 

-

Output Number 01-99

This command connects any input to any output.
The switching occurs as soon as the command is
completed. The input 00 is used to disconnect a
particular output from any input. For example,
command [I00O01] will disconnect output 1 from
any input.

Summary of Contents for MX2414RM

Page 1: ...SWITCHERS MANUAL PART NUMBER 400 0020 003 PRODUCT REVISION 0 MX2416RM MX2414RM 6 4 IN 1 OUT VGA MAC SWITCHER USER S GUIDE...

Page 2: ...satisfied customers throughout the world This manual covers MX2416RM 6 in 1 out VGA MAC Switcher MX2414RM 4 in 1 out VGA MAC Switcher TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RAC...

Page 3: ...accessories like rack mount shelf DA1298RM or rack mount ears DA1299RM and cables for optimum setup To turn off the main power be sure to remove the cord from the power outlet The power outlet socket...

Page 4: ...ke the switcher respond as a single unit Using a similar method multiple MX2416RM units can be made to operate in a Master Slave mode with all units responding to a single button selection Although ve...

Page 5: ...ompatibility Typical Video Bandwidth 400 MHz 3 dB Horizontal 15 200 kHz Vertical 30 190 Hz Cross talk 48dB 10 MHz Coupling DC Power External Power Adapter 90 140V 200 240V Power Consumption 12 watts m...

Page 6: ...s function key F2 to switch to a no signal condition The LED next to the F2 function key will light to indicate that the switcher is in this mode To resume input select switching simply press the desi...

Page 7: ...nly 2 wires one to pin 9 and one to ground are required to connect and control all of the switchers The selection of channels can also be accomplished by RS 232 on the master switcher with all slave s...

Page 8: ...s access to a variety of control capabilities PIN No PIN Designation 1 No connection 2 RS 232 Transmit 3 RS 232 Receive 4 No connection 5 Ground 6 Multiple Switcher Loop Control 7 Analog Switch Voltag...

Page 9: ...being used by the switcher such as an error string ERR will be returned If the control system being used is not setup to wait for the OK string it is important to include a 100 milliseconds delay bet...

Page 10: ...232 control MX2416RM 9 pin D Master PIN No MX2416RM 9 pin D Slave PIN No 2 3 5 5 Master Slave Control Port Connection A Master Slave configuration can be achieved also by Analog Switch Voltage using p...

Page 11: ...he same pin on all switchers MX2416RM LOOP MX2416RM LOOP 6 6 5 5 MX2416RM 9 pin D Loop The loop control pin has an internal 100k resistor to 5volts This limits the number of switchers that can be loop...

Page 12: ...706MR 6 feet VGA Male to Male CB3715MR 15 feet VGA Male to Male CB3725MR 25 feet VGA Male to Male CB3750MR 50 feet VGA Male to Male CB3775MR 75 feet VGA Male to Male CB37100MR 100 feet VGA Male to Mal...

Page 13: ...t channel or you can use the blue input channel and the blue output channel Since the MX2416RM is a relay switcher it can be used as a contact closure control or to switch virtually any type of video...

Page 14: ...harges pre paid within 2 years 90 days for cables from date of shipment to the purchaser The warranty is expressly instead of all other warranties expressed or implied Altinex neither assumes nor auth...

Reviews: