10

accommodate this need. The pin-outs for this
adapter are as follows:

9 pin “D”

Male

Description

9 pin “D”

Female

Input

7

1.2K

1

1

7

3.3K

2

2

7

6.8K

3

3

7

12K

4

4

7

22K

5

5

7

51K

6

6

7

0 short

7

NONE

5

Ground

9

The following voltages apply for selecting the
required channel:

Input number

min. (V)

nom. (V)

max. (V)

1

0.35

0.55

0.75

2

1.07

1.27

1.47

3

1.80

2.00

2.20

4

2.52

2.72

2.92

5

3.25

3.45

3.65

6

3.97

4.17

4.37

These voltage levels can be set using analog
outputs from different control systems or spare
dimmer control outputs.

7.5 MANUAL LOOP CONTROL

Loop control is used when multiple units of the

MX2416RM

 are connected to form a single

switcher. When the input channel button is pressed
the loop control pin is internally grounded and the

MX2416RM

 Switcher selects INPUT 4 as the

default input.

In this configuration, loop control pin 6 on the 9 pin
D connector is connected to the same pin on all
switchers.

MX2416RM

 LOOP

MX2416RM

 LOOP

6

6

5

5

MX2416RM

 9-pin “D” Loop

The loop control pin has an internal 100k resistor to
+5volts. This limits the number of switchers that
can be looped to a maximum of 10 switchers that
can be daisy chained together using this method.

More specifically, the output of one switcher is
connected to INPUT 6 of the next switcher. Once
loop control is enabled these switchers will
automatically switch video signals to the output of
the second switcher through INPUT 6. Keep in
mind that you are always going to have one less
input than the total number of inputs available on
all switchers. The figure above is for an 11-in 1-out
switcher.

7.6 LOOP CONTROL WITH RS-232 COMMAND

When multiple 

MX2416RM

 units are connected to

form a single switcher and RS-232 commands are
used to control these units, please connect units
according to following diagram.

If you want to make 11 by 1 switcher using two 6
by 1 switchers, the following commands need to be
used to control these switchers:

Input 1 through Input 6

[OUT01]

Input 7 through Input 11

[OUT02]

Summary of Contents for MX2414RM

Page 1: ...SWITCHERS MANUAL PART NUMBER 400 0020 003 PRODUCT REVISION 0 MX2416RM MX2414RM 6 4 IN 1 OUT VGA MAC SWITCHER USER S GUIDE...

Page 2: ...satisfied customers throughout the world This manual covers MX2416RM 6 in 1 out VGA MAC Switcher MX2414RM 4 in 1 out VGA MAC Switcher TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RAC...

Page 3: ...accessories like rack mount shelf DA1298RM or rack mount ears DA1299RM and cables for optimum setup To turn off the main power be sure to remove the cord from the power outlet The power outlet socket...

Page 4: ...ke the switcher respond as a single unit Using a similar method multiple MX2416RM units can be made to operate in a Master Slave mode with all units responding to a single button selection Although ve...

Page 5: ...ompatibility Typical Video Bandwidth 400 MHz 3 dB Horizontal 15 200 kHz Vertical 30 190 Hz Cross talk 48dB 10 MHz Coupling DC Power External Power Adapter 90 140V 200 240V Power Consumption 12 watts m...

Page 6: ...s function key F2 to switch to a no signal condition The LED next to the F2 function key will light to indicate that the switcher is in this mode To resume input select switching simply press the desi...

Page 7: ...nly 2 wires one to pin 9 and one to ground are required to connect and control all of the switchers The selection of channels can also be accomplished by RS 232 on the master switcher with all slave s...

Page 8: ...s access to a variety of control capabilities PIN No PIN Designation 1 No connection 2 RS 232 Transmit 3 RS 232 Receive 4 No connection 5 Ground 6 Multiple Switcher Loop Control 7 Analog Switch Voltag...

Page 9: ...being used by the switcher such as an error string ERR will be returned If the control system being used is not setup to wait for the OK string it is important to include a 100 milliseconds delay bet...

Page 10: ...232 control MX2416RM 9 pin D Master PIN No MX2416RM 9 pin D Slave PIN No 2 3 5 5 Master Slave Control Port Connection A Master Slave configuration can be achieved also by Analog Switch Voltage using p...

Page 11: ...he same pin on all switchers MX2416RM LOOP MX2416RM LOOP 6 6 5 5 MX2416RM 9 pin D Loop The loop control pin has an internal 100k resistor to 5volts This limits the number of switchers that can be loop...

Page 12: ...706MR 6 feet VGA Male to Male CB3715MR 15 feet VGA Male to Male CB3725MR 25 feet VGA Male to Male CB3750MR 50 feet VGA Male to Male CB3775MR 75 feet VGA Male to Male CB37100MR 100 feet VGA Male to Mal...

Page 13: ...t channel or you can use the blue input channel and the blue output channel Since the MX2416RM is a relay switcher it can be used as a contact closure control or to switch virtually any type of video...

Page 14: ...harges pre paid within 2 years 90 days for cables from date of shipment to the purchaser The warranty is expressly instead of all other warranties expressed or implied Altinex neither assumes nor auth...

Reviews: