Altinex MX2414RM User Manual Download Page 7

SWITCHERS

6

4.6 POWER UP DEFAULT SET

This function allows a user to select the channel
that will be ON at power up. To select the default
channel press the selected channel switch and
hold it for approximately 2 seconds until you hear a
beeping sound. If the unit is turned off and turned
back on, the LED of the selected channel should
light.

4.7 ANALOG OUTPUT

The analog output of the 

MX2416RM

 can be used

for controlling several switchers simultaneously.
The analog amplifier drives analog output pin 9 on
a 9-pin “D” connector. The output can swing from 0
V to approximately 5.0 V. The output impedance of
this pin is 100 Ohms and it can sink or source up to
5 mA of current. By using this output, several
switchers can operate in gang mode. To do this,
the analog output of the master switcher (pin 9) is
connected to the analog input of the slave
switchers (pin 9). Now, every time a channel is
selected on the master switcher, the output voltage
of the analog output will be set to switch all other
switchers into the same channel. The simplicity of
this approach is that only 2 wires (one to pin 9 and
one to ground) are required to connect and control
all of the switchers. The selection of channels can
also be accomplished by RS-232 on the master
switcher with all slave switchers connected through
the analog control pin. A maximum of 4 switchers
can be connected in this configuration.

APPLICATION DIAGRAM 

5

4.8 POWER SUPPLY

The 

MX2416RM

 Switcher has 5 V power supply

available on pin 8 of the 9-pin “D” connector. This
voltage can be used to drive external circuits or as
a pull up voltage for open collector type outputs.
The total current on this pin should not exceed
150 mA of continuous operation or 500 mA for 5
minutes.

4.9 BI-DIRECTIONAL SWITCHING

The 

MX2416RM

 Switchers use very high

bandwidth relays to provide you with a 400 MHz
bandwidth. Each input, when not selected, is
terminated to a 75-Ohms resistor. This is done to
make sure that video lines are always terminated
whether a channel is selected or not.

In addition to forward connection, the 

MX2416RM

can be hooked up in a reverse direction. In this
configuration one video source is selectively sent to
each of the video monitors. This capability is
referred to as bi-directional switching. In this
configuration only one display device can be
operational at any given time.

Summary of Contents for MX2414RM

Page 1: ...SWITCHERS MANUAL PART NUMBER 400 0020 003 PRODUCT REVISION 0 MX2416RM MX2414RM 6 4 IN 1 OUT VGA MAC SWITCHER USER S GUIDE...

Page 2: ...satisfied customers throughout the world This manual covers MX2416RM 6 in 1 out VGA MAC Switcher MX2414RM 4 in 1 out VGA MAC Switcher TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RAC...

Page 3: ...accessories like rack mount shelf DA1298RM or rack mount ears DA1299RM and cables for optimum setup To turn off the main power be sure to remove the cord from the power outlet The power outlet socket...

Page 4: ...ke the switcher respond as a single unit Using a similar method multiple MX2416RM units can be made to operate in a Master Slave mode with all units responding to a single button selection Although ve...

Page 5: ...ompatibility Typical Video Bandwidth 400 MHz 3 dB Horizontal 15 200 kHz Vertical 30 190 Hz Cross talk 48dB 10 MHz Coupling DC Power External Power Adapter 90 140V 200 240V Power Consumption 12 watts m...

Page 6: ...s function key F2 to switch to a no signal condition The LED next to the F2 function key will light to indicate that the switcher is in this mode To resume input select switching simply press the desi...

Page 7: ...nly 2 wires one to pin 9 and one to ground are required to connect and control all of the switchers The selection of channels can also be accomplished by RS 232 on the master switcher with all slave s...

Page 8: ...s access to a variety of control capabilities PIN No PIN Designation 1 No connection 2 RS 232 Transmit 3 RS 232 Receive 4 No connection 5 Ground 6 Multiple Switcher Loop Control 7 Analog Switch Voltag...

Page 9: ...being used by the switcher such as an error string ERR will be returned If the control system being used is not setup to wait for the OK string it is important to include a 100 milliseconds delay bet...

Page 10: ...232 control MX2416RM 9 pin D Master PIN No MX2416RM 9 pin D Slave PIN No 2 3 5 5 Master Slave Control Port Connection A Master Slave configuration can be achieved also by Analog Switch Voltage using p...

Page 11: ...he same pin on all switchers MX2416RM LOOP MX2416RM LOOP 6 6 5 5 MX2416RM 9 pin D Loop The loop control pin has an internal 100k resistor to 5volts This limits the number of switchers that can be loop...

Page 12: ...706MR 6 feet VGA Male to Male CB3715MR 15 feet VGA Male to Male CB3725MR 25 feet VGA Male to Male CB3750MR 50 feet VGA Male to Male CB3775MR 75 feet VGA Male to Male CB37100MR 100 feet VGA Male to Mal...

Page 13: ...t channel or you can use the blue input channel and the blue output channel Since the MX2416RM is a relay switcher it can be used as a contact closure control or to switch virtually any type of video...

Page 14: ...harges pre paid within 2 years 90 days for cables from date of shipment to the purchaser The warranty is expressly instead of all other warranties expressed or implied Altinex neither assumes nor auth...