SWITCHERS

8

8

5

GND

RS-232 connection of PC with DB-9 port

MX2226AT

 Terminal Block

PC DB-25 port pin no.

IBM PIN No.

MX2226AT 

Terminal

block pin

2

RX

3

TX

7

GND

RS-232 connection to 

MX2226AT

 Terminal Block

of PC with DB-25 port

Port settings of the control system or computer
being used to control the 

MX2226AT

 Switcher

should be set as follows:

BAUD Rate bps (Bits per second): 2400

Data Bits: 8

Parity: None

Stop Bits: 1

There is no software or hardware flow control
implemented. The RS-232 input has a 6-character
buffer.  The 

MX2226AT

 Switcher will not execute

additional commands until the previous command
is fully processed.

7.3 RS-232 CONTROL COMMANDS

The standard RS-232 protocol is used to control
the switcher. Commands must be issued as
shown, in ALL CAPS and with brackets [ ] that are
included in the command string.

   RS-232 Protocol:

[INP0] All channels off

[INP1] Select input 1

[INP2] Select input 2

[INP3] Select input 3

[INP4] Select input 4

[INP5] Select input 5

[INP6] Select input 6

[RSET] Reset unit to user defaults

[VERN] Returns firmware version number

After processing a valid command, an [OK] string
will be returned, followed by a command echo. For
instance, if a command, [INP1] is sent to the

MX2226AT

 Switcher, it would return the feedback

as [OK] [INP1]. The only exception is that with the
[VERN] command, which is the corresponding
firmware version of the switcher, [1.0] is returned
as feedback.

If a command is not recognized by the switcher,
an error string, [ERR], will be returned. Any
command other than the previously listed
commands will also return [ERR] feedback.

If the control system being used is not set up to,
pause for the [OK] string, it is important to include
a 100-millisecond delay between each command
to allow pause for the processing of the [OK]
[COMMAND] string.

The [RSET] function requires at least one minute
of processing time. If the Sync Delay function is
used, a 2.5-second delay should be maintained
between RS-232 commands, to account for the
time required processing Sync Delay switching.

If a key is pressed on the front panel, a feedback
string is transmitted. This is done to inform a
control system that the key has been pressed.
This feature allows several switchers used
simultaneously to operate in tandem.

7.4 FEEDBACK CODES

Key
pressed

Description

Feedback code

INPUT 1

Input Select

[OK] [INP1]

INPUT 2

Input Select

[INP2]

INPUT 3

Input Select

[INP3]

INPUT 4

Input Select

[INP4]

INPUT 5

Input Select

[INP5]

INPUT 6

Input Select

[INP6]

STEP

Step Input select

ALL OFF

Disable All Inputs

[INP0]

RESET

Reset the Switcher

[RSET] [INPx]
(x= default input)

VIDEO
OFF

Video RGB
(ON/OFF)

DELAY

Sync Delay
Switching
Enabled/Disabled

Summary of Contents for MX2226AT

Page 1: ...SWITCHERS MANUAL PART NUMBER 400 0030 003 MX2226AT 6 IN 1 OUT RGBHV SWITCHER USER S GUIDE ...

Page 2: ...CATION 3 MX2226AT DESCRIPTION 4 APPLICATION DIAGRAM 5 INSTALLATION 5 OPERATION 6 OPERATION FROM THE FRONT PANEL 6 RS 232 CONTROL 7 RS 232 CONTROL 8 FEEDBACK CODES 8 MASTER SLAVE CONTROL RS 232 9 LOOP CONTROL 9 FREQUENTLY ASKED QUESTIONS 10 CABLES AND ACCESSORIES 11 TROUBLESHOOTING GUIDE 11 ALTINEX POLICY 12 LIMITED WARRANTY 12 RETURN POLICY 12 CONTACT INFORMATION 12 ...

Page 3: ...op of the MX2226AT If the MX2226AT is to be mounted to a table or wall use only ALTINEX made DA1292FC 1U High Rack Mount and cables for optimum setup To turn off the main power be sure to remove the cord from the power outlet The power outlet socket should be installed as near to the equipment as possible and should be easily accessible Do not pull the power cord or any cable that is attached to t...

Page 4: ...s into a no display mode Multiple MX2226AT units may be looped together to create a larger switcher with more than six inputs By connecting two pins on the control port of each switcher used the multiple switchers will act as a single switcher when controlled from the front panel The MX2226AT delivers an extremely high bandwidth of 400 MHz allowing it to remain transparent to even very high resolu...

Page 5: ... Impedance Pass through Frequency Compatibility Typical Video Bandwidth 400 MHz 3 dB Horizontal 15 200 kHz Vertical 30 190 Hz Horizontal Position Range 20 Cross talk 48 dB 10 MHz Coupling DC Power 90 140V 200 240V Selectable Power Consumption 12 watts max Table 3 MX2226AT Electrical DESCRIPTION OF MODEL NAME 4 ...

Page 6: ...SWITCHERS 5 5 APPLICATION DIAGRAM 5 ...

Page 7: ...NPUT This function allows a user to define which input will be selected at power up To define the default power on the input channel while turning ON the unit press the desired channel switch and hold it for approximately 2 seconds until you hear a short beep Turn the unit OFF and then turn it back on again The LED of the selected input should be ON For factory default the input is set to INPUT1 7...

Page 8: ... H V SYNC or CSYNC of the selected source will continue to be sent to the display This feature can be very helpful when the user does not want the display to go into a no display or no signal mode e g some data monitors will display a blue screen if no signal is present To disable the video portion of the selected input press the video off button once the LED on the top button should light up To e...

Page 9: ... it would return the feedback as OK INP1 The only exception is that with the VERN command which is the corresponding firmware version of the switcher 1 0 is returned as feedback If a command is not recognized by the switcher an error string ERR will be returned Any command other than the previously listed commands will also return ERR feedback If the control system being used is not set up to paus...

Page 10: ...d be looped Keep in mind that the Looping Configuration will eliminate one usable input for each looped unit For example if two 6 in 1 out switchers were looped together there would be 11 usable inputs The loop control feature forces all looped units to select input 6 so that the incoming signal will automatically pass through If input from switcher no 1 is selected then input no 6 is automaticall...

Page 11: ...ter cables for several countries are available through ALTINEX as listed in section 9 7 How do I control several You cannot control multiple MX2226AT Switchers switchers independently with one RS 232 card in a control system independently with one RS 232 control card at this time The unit does not have user selectable ID codes or command delimiters So a command sent by a control card cannot be int...

Page 12: ...B5100PL 5BM00065BM 6 feet 5 BNC M to 5 BNC M CB5100PL 12 feet 5 BNC M to 5 BNC M 5BM00125BM CB5100PL 5BM00255BM 25 feet 5 BNC M to 5 BNC M CB5100PL 5BM00505BM 50 feet 5 BNC M to 5 BNC M CB5100PL 5BM00755BM 75 feet 5 BNC M to 5 BNC M CB5100PL 5BM01005BM 100 feet 5 BNC M to 5 BNC M CB5100PL 5BM01505BM 150 feet 5 BNC M to 5 BNC M CB5100PL 5BM02005BM 200 feet 5 BNC M to 5 BNC M CB5100PL 5BM02505BM 250...

Page 13: ...dent 11 2 RETURN POLICY It is very important to ALTINEX that you receive the products that you have ordered and that this product meets your expectations In the unlikely event that an ALTINEX product needs to be returned please follow the policy below ALTINEX will accept product returns for a period of 30 days from authorized ALTINEX dealers Products must be returned in an unopened package If a pr...

Reviews: