Why?

OFF mode.

3

Can the

MX2226AT

be used to
pass
Composite
Video,
S-Video, and
Component
Video?

Yes, simply use the
corresponding channels to
pass the signals (e.g. For
composite video, you may
use the red channel or you
may use the blue channel).
Since the 

MX2226AT

 

is a

relay switcher, it can be
used as a contact closure
control or to switch virtually
to any type of video, sync,
audio, or even RS-232
signals.

4

What is the
difference
between the
VIDEO OFF
button and
the ALL OFF
button?

When the ALL OFF button
is pressed none of the
inputs is connected by the

MX2226AT

, while the

VIDEO OFF button disables
the video portion of the
selected input but continues
to send the sync portion of
the signal.

5

Can I use
contact
closures to
control the

MX2226AT

?

No, the 

MX2226AT 

is not

designed for control
through contact closures at
this time. To use contact
closures you may consider
using the ALTINEX

CP7317RS

 Controller to

convert contact closures to
RS- 232 commands.

6

Can the

MX2226AT

Switcher be
used outside
of the United
States?

Yes, the 

MX2226AT

 uses a

universal internal power
supply, enabling it to be
used throughout the world.
First, make sure that you
have the voltage setting in
the correct position, and
second make sure to use
the proper adapter cable for
the country where it will be
used. Adapter cables for
several countries are
available through ALTINEX
as listed in section 9.

7

How do I
control several

You cannot control multiple

MX2226AT 

Switchers

switchers
independently
with one RS-
232 card in a
control
system?

independently with one RS-
232 control card at this
time. The unit does not
have user-selectable ID
codes or command
delimiters. So, a command
sent by a control card
cannot be interpreted
individually by each switch.
If this is a required feature,
the units can be pre-set at
the factory for individual ID
codes. Please call
ALTINEX at 1-714-990-
2300 for details.

8

Does the
”Loop”
connection on
the 4 pin
Terminal
Block allow
me to loop
RS-232 to
another
switcher?

No, the ”Loop” feature on
this connector allows
multiple switchers to be
connected and operated as
one large switcher with
more than six inputs. For
the solution to this, see the
Master/Slave control
operations section, 7.5.

9

Why doesn’t
my control
system work
when I have
the sync
Delay feature
activated?

The Sync Delay feature
requires 2.5 seconds to be
executed. You must make
sure that your control
system of at least 2.5
seconds allows for the
delay between two
consecutive commands.

CABLES AND ACCESSORIES

9

Model No.

Description

RACK MOUNTING ACCESSORIES

DA1293FC

POWER CABLES

PC5301US

Power cable for US

PC5302UK

Power cable for England

PC5303AU

Power cable for Australia

PC5304GR

Power cable for Germany

HIGH RESOLUTION 5 BNC TO 5 BNC COAXIAL

CABLE

CB4200MR

Bulk cable (500 feet minimum)

CB4203MR

3 feet, 5-BNC M to 5-BNC M

Summary of Contents for MX2226AT

Page 1: ...SWITCHERS MANUAL PART NUMBER 400 0030 003 MX2226AT 6 IN 1 OUT RGBHV SWITCHER USER S GUIDE ...

Page 2: ...CATION 3 MX2226AT DESCRIPTION 4 APPLICATION DIAGRAM 5 INSTALLATION 5 OPERATION 6 OPERATION FROM THE FRONT PANEL 6 RS 232 CONTROL 7 RS 232 CONTROL 8 FEEDBACK CODES 8 MASTER SLAVE CONTROL RS 232 9 LOOP CONTROL 9 FREQUENTLY ASKED QUESTIONS 10 CABLES AND ACCESSORIES 11 TROUBLESHOOTING GUIDE 11 ALTINEX POLICY 12 LIMITED WARRANTY 12 RETURN POLICY 12 CONTACT INFORMATION 12 ...

Page 3: ...op of the MX2226AT If the MX2226AT is to be mounted to a table or wall use only ALTINEX made DA1292FC 1U High Rack Mount and cables for optimum setup To turn off the main power be sure to remove the cord from the power outlet The power outlet socket should be installed as near to the equipment as possible and should be easily accessible Do not pull the power cord or any cable that is attached to t...

Page 4: ...s into a no display mode Multiple MX2226AT units may be looped together to create a larger switcher with more than six inputs By connecting two pins on the control port of each switcher used the multiple switchers will act as a single switcher when controlled from the front panel The MX2226AT delivers an extremely high bandwidth of 400 MHz allowing it to remain transparent to even very high resolu...

Page 5: ... Impedance Pass through Frequency Compatibility Typical Video Bandwidth 400 MHz 3 dB Horizontal 15 200 kHz Vertical 30 190 Hz Horizontal Position Range 20 Cross talk 48 dB 10 MHz Coupling DC Power 90 140V 200 240V Selectable Power Consumption 12 watts max Table 3 MX2226AT Electrical DESCRIPTION OF MODEL NAME 4 ...

Page 6: ...SWITCHERS 5 5 APPLICATION DIAGRAM 5 ...

Page 7: ...NPUT This function allows a user to define which input will be selected at power up To define the default power on the input channel while turning ON the unit press the desired channel switch and hold it for approximately 2 seconds until you hear a short beep Turn the unit OFF and then turn it back on again The LED of the selected input should be ON For factory default the input is set to INPUT1 7...

Page 8: ... H V SYNC or CSYNC of the selected source will continue to be sent to the display This feature can be very helpful when the user does not want the display to go into a no display or no signal mode e g some data monitors will display a blue screen if no signal is present To disable the video portion of the selected input press the video off button once the LED on the top button should light up To e...

Page 9: ... it would return the feedback as OK INP1 The only exception is that with the VERN command which is the corresponding firmware version of the switcher 1 0 is returned as feedback If a command is not recognized by the switcher an error string ERR will be returned Any command other than the previously listed commands will also return ERR feedback If the control system being used is not set up to paus...

Page 10: ...d be looped Keep in mind that the Looping Configuration will eliminate one usable input for each looped unit For example if two 6 in 1 out switchers were looped together there would be 11 usable inputs The loop control feature forces all looped units to select input 6 so that the incoming signal will automatically pass through If input from switcher no 1 is selected then input no 6 is automaticall...

Page 11: ...ter cables for several countries are available through ALTINEX as listed in section 9 7 How do I control several You cannot control multiple MX2226AT Switchers switchers independently with one RS 232 card in a control system independently with one RS 232 control card at this time The unit does not have user selectable ID codes or command delimiters So a command sent by a control card cannot be int...

Page 12: ...B5100PL 5BM00065BM 6 feet 5 BNC M to 5 BNC M CB5100PL 12 feet 5 BNC M to 5 BNC M 5BM00125BM CB5100PL 5BM00255BM 25 feet 5 BNC M to 5 BNC M CB5100PL 5BM00505BM 50 feet 5 BNC M to 5 BNC M CB5100PL 5BM00755BM 75 feet 5 BNC M to 5 BNC M CB5100PL 5BM01005BM 100 feet 5 BNC M to 5 BNC M CB5100PL 5BM01505BM 150 feet 5 BNC M to 5 BNC M CB5100PL 5BM02005BM 200 feet 5 BNC M to 5 BNC M CB5100PL 5BM02505BM 250...

Page 13: ...dent 11 2 RETURN POLICY It is very important to ALTINEX that you receive the products that you have ordered and that this product meets your expectations In the unlikely event that an ALTINEX product needs to be returned please follow the policy below ALTINEX will accept product returns for a period of 30 days from authorized ALTINEX dealers Products must be returned in an unopened package If a pr...

Reviews: