6

Step 1

. Make sure that the window on the fuse is

set to the proper AC voltage in your
country. An incorrect setting can result in
unit damage, which is not covered by
warranty.

Step 2

. Connect the power cord to the unit and

plug it into the power outlet. Make sure
that the power indicator LED is on.

Step 3

. Connect the cables from the source to the

input connectors and connect display
devices, such as monitors or projectors to
the outputs. Shielded, high quality coaxial
cables are recommended for video cable
runs.

Step 4.

Verify that image on the display is perfect.
The unit will operate successfully as long
as all specifications are followed.

Step 5.

Connect the Rx, Tx, and Gnd signals from
the control system as per section 7.2 if
the 

MX2226AT

 must be controlled

remotely.

OPERATION

7

7.1 OPERATION FROM THE FRONT PANEL

The front panel of the 

MX2226AT

 provides access

to essentially all of the switcher’s capabilities. It
has three sections: input select, switcher
functions, and output control.

7.1.2 INPUT SELECT SECTION

SELECTION OF INPUT

:

When the buttons INPUT1 through INPUT6
are pressed, the corresponding INPUT will be
selected. The LED on top of the bottom front
panel will TURN ON simultaneously to indicate
which input has been selected. When
connected as a 1-in 6-out switcher, the outputs
are selected through the INPUT SELECT
section.

SET DEFAULT POWER UP INPUT

:

This function allows a user to define which
input will be selected at power up. To define
the default power on the input channel, while
turning ON the unit, press the desired channel
switch and hold it for approximately 2 seconds
until you hear a short beep. Turn the unit OFF
and then turn it back on again. The LED of the
selected input should be ON. For factory
default the input is set to INPUT1.

7.1.2 SWITCHER FUNCTIONS SECTION

RESET

:

This function allows a user to reset the
switcher without unplugging the unit. Press the
RESET

 

button

 

and

 

hold it for approximately 2

seconds. When you hear a beeping sound,
release the button. All LEDs on the front panel
will flash simultaneously. The

 

current

connection of input to output will be lost and
power up input will be loaded. The user-set
defaults for SOUND and DEFAULT CHANNEL
will not be changed by the RESET function.

ALL

 

OFF

:

This function allows a user to turn OFF the
output of the 

MX22226AT

. It is very useful

when the 

MX2226AT

 Switcher is used in an

application, where the display must be blanked
periodically. Press this button to switch to a
“no signal” condition. To resume Input Select
switching, simply press the desired INPUT or
the STEP function.

SOUND

:

This function allows a user to have audible
feedback when the buttons are pressed. The
factory default is set to have audible feedback
ON through to a beep. In some situations
however, sound may be undesirable. To
disable the beeping sound, press this button
and hold it for approximately 2 seconds until a
beep is heard. After the sound is disabled, to
re-enable the sound, repeat the same
procedure.

Summary of Contents for MX2226AT

Page 1: ...SWITCHERS MANUAL PART NUMBER 400 0030 003 MX2226AT 6 IN 1 OUT RGBHV SWITCHER USER S GUIDE ...

Page 2: ...CATION 3 MX2226AT DESCRIPTION 4 APPLICATION DIAGRAM 5 INSTALLATION 5 OPERATION 6 OPERATION FROM THE FRONT PANEL 6 RS 232 CONTROL 7 RS 232 CONTROL 8 FEEDBACK CODES 8 MASTER SLAVE CONTROL RS 232 9 LOOP CONTROL 9 FREQUENTLY ASKED QUESTIONS 10 CABLES AND ACCESSORIES 11 TROUBLESHOOTING GUIDE 11 ALTINEX POLICY 12 LIMITED WARRANTY 12 RETURN POLICY 12 CONTACT INFORMATION 12 ...

Page 3: ...op of the MX2226AT If the MX2226AT is to be mounted to a table or wall use only ALTINEX made DA1292FC 1U High Rack Mount and cables for optimum setup To turn off the main power be sure to remove the cord from the power outlet The power outlet socket should be installed as near to the equipment as possible and should be easily accessible Do not pull the power cord or any cable that is attached to t...

Page 4: ...s into a no display mode Multiple MX2226AT units may be looped together to create a larger switcher with more than six inputs By connecting two pins on the control port of each switcher used the multiple switchers will act as a single switcher when controlled from the front panel The MX2226AT delivers an extremely high bandwidth of 400 MHz allowing it to remain transparent to even very high resolu...

Page 5: ... Impedance Pass through Frequency Compatibility Typical Video Bandwidth 400 MHz 3 dB Horizontal 15 200 kHz Vertical 30 190 Hz Horizontal Position Range 20 Cross talk 48 dB 10 MHz Coupling DC Power 90 140V 200 240V Selectable Power Consumption 12 watts max Table 3 MX2226AT Electrical DESCRIPTION OF MODEL NAME 4 ...

Page 6: ...SWITCHERS 5 5 APPLICATION DIAGRAM 5 ...

Page 7: ...NPUT This function allows a user to define which input will be selected at power up To define the default power on the input channel while turning ON the unit press the desired channel switch and hold it for approximately 2 seconds until you hear a short beep Turn the unit OFF and then turn it back on again The LED of the selected input should be ON For factory default the input is set to INPUT1 7...

Page 8: ... H V SYNC or CSYNC of the selected source will continue to be sent to the display This feature can be very helpful when the user does not want the display to go into a no display or no signal mode e g some data monitors will display a blue screen if no signal is present To disable the video portion of the selected input press the video off button once the LED on the top button should light up To e...

Page 9: ... it would return the feedback as OK INP1 The only exception is that with the VERN command which is the corresponding firmware version of the switcher 1 0 is returned as feedback If a command is not recognized by the switcher an error string ERR will be returned Any command other than the previously listed commands will also return ERR feedback If the control system being used is not set up to paus...

Page 10: ...d be looped Keep in mind that the Looping Configuration will eliminate one usable input for each looped unit For example if two 6 in 1 out switchers were looped together there would be 11 usable inputs The loop control feature forces all looped units to select input 6 so that the incoming signal will automatically pass through If input from switcher no 1 is selected then input no 6 is automaticall...

Page 11: ...ter cables for several countries are available through ALTINEX as listed in section 9 7 How do I control several You cannot control multiple MX2226AT Switchers switchers independently with one RS 232 card in a control system independently with one RS 232 control card at this time The unit does not have user selectable ID codes or command delimiters So a command sent by a control card cannot be int...

Page 12: ...B5100PL 5BM00065BM 6 feet 5 BNC M to 5 BNC M CB5100PL 12 feet 5 BNC M to 5 BNC M 5BM00125BM CB5100PL 5BM00255BM 25 feet 5 BNC M to 5 BNC M CB5100PL 5BM00505BM 50 feet 5 BNC M to 5 BNC M CB5100PL 5BM00755BM 75 feet 5 BNC M to 5 BNC M CB5100PL 5BM01005BM 100 feet 5 BNC M to 5 BNC M CB5100PL 5BM01505BM 150 feet 5 BNC M to 5 BNC M CB5100PL 5BM02005BM 200 feet 5 BNC M to 5 BNC M CB5100PL 5BM02505BM 250...

Page 13: ...dent 11 2 RETURN POLICY It is very important to ALTINEX that you receive the products that you have ordered and that this product meets your expectations In the unlikely event that an ALTINEX product needs to be returned please follow the policy below ALTINEX will accept product returns for a period of 30 days from authorized ALTINEX dealers Products must be returned in an unopened package If a pr...

Reviews: