background image

MUSE™: 

HDMI+POWER+IR Transmitter

 

User’s Guide

 

400-0572-008 

 

 
 
 
 
 
 

 

Welcome!

Everyone at Altinex greatly appreciates your purchase of the MUSE 
Transmitter. We are confident that you will find it both reliable and 
simple to use. If you need support, please do not hesitate to call us at 714-
990-2300.  

We are committed to developing unique and state of the art Signal 
Management Solutions

®

 for demanding audiovisual installations. Welcome 

to the Altinex family of satisfied customers around the world. 

 
1. Precautions and Safety Warnings 

Please read this manual entirely before using your MU400-111 
Transmitter. You can download a full version of this manual on 

www.altinex.com

These safety instructions are to ensure the reliable 

operation of your MU400-111 Transmitter and to prevent fire and shock 
hazards. Please read them carefully and heed all warnings. 

1.1 General 

 

The MU400-111 Transmitter does not contain any user serviceable 
parts. Only qualified ALTINEX service personnel may perform 
product service. 

 

The MU400-111 Transmitter is safety tested and ETL listed.  

 

The MU400-111 Transmitter incorporates a proprietary technology 
for the transmission of display power and video over a low voltage 
CAT-6 cable. 

1.2 Installation Precautions 

 

To prevent fire and shock, do not expose this unit to water or 
moisture. Do not place the MUSE Transmitter in direct sunlight, 
near heaters or heat-radiating appliances, or near any liquid. 
Exposure to direct sunlight, smoke, or steam can harm internal 
components. 

 

Handle the MU400-111 Transmitter carefully. Dropping or jarring 
can cause internal and external damage. 

 

Do not pull any cables that are attached to the MU400-111 
Transmitter. 

 

For optimal safety, apply AC power only after the system is installed 
with all wires connected.  

1.3 Cleaning 

 

Clean the MU400-111 Transmitter only with a dry cloth. Never use 
detergents or solvents such as alcohol or thinner. Do not use a wet 
cloth or water to clean. 

1.4 FCC Notice 

 

This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) This device may not 
cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause 
undesired operation. 

 

This equipment has been tested and found to comply with the limits 
for a Class A digital device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in 
accordance with the instructions found herein, may cause harmful 
interference to radio communications. Operation of this equipment 
in a residential area is likely to cause harmful interference in which 
case the user will be required to correct the interference at his own 
expense. 

 

Any changes or modifications to the unit not expressly approved by 
ALTINEX, Inc. could void the user’s authority to operate the 
equipment. 

 

2. Installation Procedures 

Note: 

The CAT-6 type cable is a critical component to the functionality of the unit. Use only the recommended cables for optimum performance. See the 
minimum cable requirements on the technical specifications page. 

Step 1. 

For detailed information, download and read the entire manual a

www.altinex.com

.   

Step 2. 

Connect the HDMI source to the input of the MU400-111 using a standard HDMI cable.  

Step 3. 

Connect the MU400-111 Transmitter to the MU500-112 Receiver using terminated, 
unshielded CAT-6 cable. The required cable gauge is AWG23, to achieve full power.  
(Note: Use the MU400-111 Transmitter only with the Altinex MU500-112 Receiver) 

Step 4. 

Connect AC power to the MU400-111 Transmitter. As soon as the MU400-111 Transmitter 
authenticates the MU500-112 Receiver, full power will be provided to the MU500-112 
Receiver, followed by the HDMI signal.  It may take several minutes for the monitor to power up and for an image to be displayed on the monitor. 

Step 5.  

For IR (Infrared Control) operation, use Altinex accessories: AC301-114 Emitter and  
AC301-115 IR Receiver. 

Step 6. 

The MUSE Transmitter is now ready for operation. 

 
 

 
3. Warranty and Return Policies 

Please visit the ALTINEX website at 

www.altinex.com

 for details on warranty and return policies. In the case of a unit needing repair, please fill out the RMA 

(return material authorization) form located on the bottom left hand corner of the Altinex homepage. Once filled out, please email the form to 
[email protected].

 

Summary of Contents for MUSE MU400-111

Page 1: ...including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These lim...

Page 2: ...unterliegt den folgenden beiden Bedingungen 1 Dieses Ger t darf keine gef hrlichen St rungen verursachen und 2 Dieses Ger t muss m gliche empfangene Funkst rungen und dadurch verursachte Funktionsst r...

Page 3: ...e MU400 111 Transmitter is monitored for power consumption and when power is exceeded the output is turned off to protect all components The MUSE can power a 46 to 52 display with a maximum continuous...

Page 4: ...nd wenn die Leistung berschritten wird wird die Ausgabe zum Schutz aller Komponenten abgeschaltet MUSE kann einen 46 52 Zoll Bildschirm mit maximalem Stromverbrauch von 150 Watt betreiben Das Empfangs...

Page 5: ...8 Application Diagram 9 Internal View Dimension Diagrams 10 Recommended Components Operation 11 Troubleshooting Guide 12 German Power Calculations 13 14 Technical Specifications 15 Application Diagram...

Page 6: ...233 150 150 228 175 148 223 200 146 218 225 144 213 250 142 208 275 140 202 300 138 197 Available Power Calculations Example Calculations for 300ft Cable 1 Resistance Resistance of a single strand of...

Page 7: ...51V x 2 9A 148W Power to Receiver Power Used by Receiver Available Power Example 148W 10W 138W Available Surge Power Calculations Example Calculations for 300ft Cable 1 Voltage Surge Current 4 5 A Su...

Page 8: ...el Color Clear Zinc MTBF calc 38 000 hrs Transmitter Height 2 5 in 64 mm Width no mounting ears 3 3 in 84 mm Depth 6 9 in 175 mm Weight 2 2 lb 1 0 kg T Operating 10 C 50 C T Maximum 75 C Humidity 90 n...

Page 9: ...cation Diagrams Diagram 1 Typical Setup Table 5 Status of MU400 11 Transmitter TX STATUS POWER PAIR NORMAL ON ON IDLE ON SLOW BLINKING FAULT FAST BLINKING FAST BLINKING VIDEO STATUS LINK VIDEO LINK AC...

Page 10: ...MUSE HDMI POWER IR Transmitter Receiver User s Guide 400 0572 008 10 Diagram 2 Transmitter Internal View Diagram 3 Transmitter Dimensions...

Page 11: ...hat have very large initial current requirements These are typically Plasma displays or low cost non Energy Star compliant displays If you have difficulty powering up a display adjust the settings to...

Page 12: ...12 Receiver from the MU400 111 Transmitter If the problem is fixed wait 10 seconds and then reconnect the MU500 112 Receiver 3 Reconnect the display if the problem returns check the display power requ...

Page 13: ...150 233 150 150 228 175 148 223 200 146 218 225 144 213 250 142 208 275 140 202 300 138 197 Verf gbare Leistungskalkulationen Beispielberechnung f r ein 91m Kabel 4 Resistance Resistance of a single s...

Page 14: ...A 148W Power to Receiver Power Used by Receiver Available Power Example 148W 10W 138W Available Surge Power Calculations Example Calculations for 300ft Cable 3 Voltage Surge Current 4 5 A Surge Curren...

Page 15: ...lear Zinc MTBF calc 38 000 hrs Transmitter Height 2 5 in 64 mm Width no mounting ears 3 3 in 84 mm Depth 6 9 in 175 mm Weight 2 2 lb 1 0 kg T Operating 10 C 50 C T Maximum 75 C Humidity 90 non condens...

Page 16: ...s Diagram 2 Typical Setup Table 5 Status of MU400 11 Transmitter TX STATUS POWER PAIR NORMAL ON ON IDLE ON SLOW BLINKING FAULT FAST BLINKING FAST BLINKING VIDEO STATUS LINK VIDEO LINK ACTIVE ON LINK F...

Page 17: ...MU400 111 User s Guide 400 0572 008 17 Diagram 2 Transmitter Internal View Diagram 3 Transmitter Dimensions...

Page 18: ...dschirme mit hohen internen Stromanforderungen Es handelt sich dabei haupts chlich um Plasmabildschirme oder billige Anzeigen die nicht den Energy Star Anforderungen entsprechen Wenn Sie Schwierigkeit...

Page 19: ...schlie en den MU500 112 Receiver wieder an 3 Schlie en Sie den Bildschirm wieder an Wenn das Problem wiederkehrt pr fen Sie die Stromanforderungen des Bildschirms Hinweis Es steht ausreichen Strom be...

Reviews: