background image

MT317-101

 

 

User’s Guide

 

400-0660-001 

10 

 

8. Troubleshooting Guide

We have carefully tested and have found no problems in the supplied MT317

–101. However, we would like to offer suggestions for the 

following: 

Extender 

Symptom  

Resolution 

LEDs Are OFF  

  Make sure the unit is plugged all the way into the MultiTasker slot. 

  Make sure the MultiTasker enclosure is connected to AC power and that the power switch on the 

front of the unit is turned on. 

Check Transmitter 

The MT317

–101 requires a valid fiber optic signal with HDMI video in order to display video on the 

HDMI output. The signal must terminate into a compatible Altinex receiver: 

MT317-102, FR317-102. 

  Check the receiver; verify power is present. 

  Make sure the transmitter LEDs indicate power and status. 

No Display 

  Check the source (transmitter side) and make sure there is a signal present. 

  Make sure the source connected to the transmitter has power and is turned on. 

  Run a short fiber cable between the transmitter and receiver. The cable in question may be too long 

or of inferior quality. If the image appears, check the cable length and quality. Look for any damage 
or creases in the cable. 

Poor Output Image 

  The source resolution may not be compatible with the projector or other display device. Try other 

resolutions from the source. 

  The source and display may not be compatible. Connect the source directly to the input of the 

projector or other display device. If the image is poor the devices may be incompatible.  

  Run a different cable. The cable in question may be too long or of inferior quality. 

System Failure 

Please call the Altinex Customer Service Department at (714) 990-2300 to have the unit repaired.  

 

 

 

 

Summary of Contents for MT317-101

Page 1: ...ested and found to comply with the limits for a Class B digital device pursuant to Part 2 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when...

Page 2: ...i 720P 576P 480P 4Kx2K 30Hz Receiver MT317 102 FR317 102 Cable LC UPC to LC UPC Duplex OM3 Multimode Range Longer range options are available 984 ft 300 m Table 1 MT317 101 General Mechanical MT317 10...

Page 3: ...The transmitter may be an Altinex MultiTasker card inside of another enclosure at a remote location or the transmitter can be Altinex s stand alone transmitter FR317 101 The use of fiber optic cable a...

Page 4: ...MT317 101 User s Guide 400 0660 001 4 6 Application Diagrams Diagram 1 Typical Setup...

Page 5: ...MT317 101 User s Guide 400 0660 001 5 Diagram 2 Internal View...

Page 6: ...valid command If the command requested information from the card the feedback generated by the card is the acknowledgement of having received a valid command C04 Card C4 slot 4 executed a valid comman...

Page 7: ...er up Input 3 is the active signal This command only saves the command sent Use the CiiS command to save all current settings This command is common to all cards but there are no features to save on t...

Page 8: ...t SFTCii Example Reset the card in slot by sending SFTC4 The card responds with RSTC04 indicating the card is resetting 14 STA This command enables and disables automatic feedback from the card The fe...

Page 9: ...DISP Return card information 6 FRST Factory reset 7 GROUP Set or read group number 8 HWEN Hardware enable disable 9 MOD Return card model 10 PRG Firmware update mode 11 PWR Return card power in watts...

Page 10: ...dicate power and status No Display Check the source transmitter side and make sure there is a signal present Make sure the source connected to the transmitter has power and is turned on Run a short fi...