background image

MT317-101 HDMI Over Fiber Tx  

User’s Guide

 

400-0660-001 

 

 

Welcome!

Everyone at Altinex greatly appreciates your purchase of the 
MT317

–101. We are confident that you will find it to be reliable 

and simple to use. If you need support, please do not hesitate to 
call us at 714-990-2300.  

At Altinex, we are committed to developing unique and state of 
the art Signal Management Solutions

®

 for demanding audiovisual 

installations. Welcome to the Altinex family of satisfied customers 
around the world! 

1. Precautions and Safety Warnings 

  Please read this manual entirely before using your 

MT317

–101. You can download a full version of this 

manual a

www.altinex.com

These instructions are to 

ensure the reliable operation of your switcher and to 
prevent fire and shock hazards. Please read them 
carefully and heed all warnings. 

1.1 General 

  Qualified Altinex service personnel or their authorized 

representatives must perform all service. 

1.2 Installation Precautions 

  To prevent fire or shock, do not expose this unit to water 

or moisture. Do not place the MT317

–101 in direct 

sunlight, near heaters or heat-radiating appliances, or near 
any liquid. Exposure to direct sunlight, smoke, or steam 
can harm internal components. 

  Handle carefully; dropping or jarring can cause damage. 

  Do not pull any cables attached to the MT317

–101. 

1.3 Cleaning 

  Clean the MT317

–101 with a dry cloth only. Never use 

strong detergents or solvents such as alcohol or thinner. 
Do not use a wet cloth or water to clean the card. Do not 
clean or touch any component or PCB. 

1.4 FCC Notice 

  This device complies with Part 15 of the FCC Rules. 

Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) 
this device must accept any interference received, 
including interference that may cause undesired operation. 

  This equipment has been tested and found to comply with 

the limits for a Class B digital device, pursuant to Part 2 of 
the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference when 
the equipment is operated in a commercial environment. 
This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in 
accordance with the instructions found herein, may cause 
harmful interference to radio communications. Operation 
of this equipment in a residential area is likely to cause 
harmful interference in which case the user will be 
required to correct the interference at their own expense. 

  Any changes or modifications to the unit not expressly 

approved by Altinex, Inc. could void the 

user’s authority to 

operate the equipment. 

 

 

2. Installation Procedures 

Note: 

Download and read the entire online manual to become familiar with the MT317

–101 and for detailed installation instructions 

and configuration details. 

Step 1:  Turn off power to the MultiTasker enclosure. 

Step 2:  Remove a slot cover to make room for the MT317

–101. 

Step 3.  Slide the MT317

–101 into the enclosure making note of the slot number. This is needed for control. 

Step 4.  Secure the card to the enclosure using the thumb screws attached to the card. 

Step 5.  Restore power to the enclosure and wait for the system to initialize. Once ready, press the button on the enclosure front panel 

to verify the new card is recognized.  

Step 6.  Connect an LC UPC to LC UPC Duplex OM3 Multimode cable between the MT317

–101 transmitter and a compatible receiver;  

MT317-102 or FR317-102. 

Step 7.  On a LAN, the enclosure IP can be discovered via a UDP broa

dcast of “?Altinex” to port 30305. 

3. Warranty and Return Policies 

Please visit the Altinex website a

www.altinex.com

 for details on warranty and return policies. In the case of a unit needing repair, 

please complete a RMA (return material authorization) form by clicking the Warranty link located on the bottom of the Altinex 
homepage. Once completed, please email the form to 

[email protected]

Summary of Contents for MT317-101

Page 1: ...ested and found to comply with the limits for a Class B digital device pursuant to Part 2 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when...

Page 2: ...i 720P 576P 480P 4Kx2K 30Hz Receiver MT317 102 FR317 102 Cable LC UPC to LC UPC Duplex OM3 Multimode Range Longer range options are available 984 ft 300 m Table 1 MT317 101 General Mechanical MT317 10...

Page 3: ...The transmitter may be an Altinex MultiTasker card inside of another enclosure at a remote location or the transmitter can be Altinex s stand alone transmitter FR317 101 The use of fiber optic cable a...

Page 4: ...MT317 101 User s Guide 400 0660 001 4 6 Application Diagrams Diagram 1 Typical Setup...

Page 5: ...MT317 101 User s Guide 400 0660 001 5 Diagram 2 Internal View...

Page 6: ...valid command If the command requested information from the card the feedback generated by the card is the acknowledgement of having received a valid command C04 Card C4 slot 4 executed a valid comman...

Page 7: ...er up Input 3 is the active signal This command only saves the command sent Use the CiiS command to save all current settings This command is common to all cards but there are no features to save on t...

Page 8: ...t SFTCii Example Reset the card in slot by sending SFTC4 The card responds with RSTC04 indicating the card is resetting 14 STA This command enables and disables automatic feedback from the card The fe...

Page 9: ...DISP Return card information 6 FRST Factory reset 7 GROUP Set or read group number 8 HWEN Hardware enable disable 9 MOD Return card model 10 PRG Firmware update mode 11 PWR Return card power in watts...

Page 10: ...dicate power and status No Display Check the source transmitter side and make sure there is a signal present Make sure the source connected to the transmitter has power and is turned on Run a short fi...

Reviews: