altimo CH601SS Instruction Manual Download Page 6

 

WARNING AND SAFETY PRECAUTIONS 

 

 

In case of fire, isolate the power to the hood and any other cooking devices.  
(unplug the appliance or turn off at the main switch). 

 

Keep your product clean. Build-up of deposits can increase the risk of fire. 

 

Isolate the appliance before any maintenance operations.  
(Unplug the appliance or turn off at the main switch.) 

 

When extracting air using an electric cooker hood or other devices operating 
simultaneously, the negative pressure in the room must not exceed 4 Pa (4 X 10 
bar). Ensure adequate ventilation. 

 

Care and attention must be observed when using this appliance simultaneously 
with other appliances affecting ambient air. By its nature of discharging ambient 
air in a limited environment this hood could adversely affect the levels of air 
increasing risk of combustion. Items to be considered include burners of gas, 
diesel, coal, wood, burning heaters, and shower heaters. This warning applies to 
discharged air only and does not apply to re-circled uses without flue. Gas or fuel 
oil burning appliances, such as room heaters, which share the same 
environment with your product, must be fully insulated from the exhaust of this 
product or they must be hermetical. 

 

When connecting a flue to your product use ducting pipes with a diameter of 
150mm or 120mm. Minimise both the length and number of connections to the 
outside to promote good flow and improved operation. 

 

Children must not play with the appliance. 

 

For your safety use a fuse rated ‘MAX 6A’ for your hood. 

 

Handle and dispose of packaging materials safely, as they pose a risk keep 
them away from children. 

 

Any damage to the power supply cable must be replaced by the manufacturer, 
an authorised service location or any other qualified person, to avoid any 
dangerous situation. 

 

In case of fire, isolate the cooker hood and cooking appliances, cover the flame 
with a damp cloth. Never use water to extinguish the fire. 

 

When cooking appliances are in operation accessible parts could be hot. 

 

This appliance is not intended to be used by people with physical, sensory and 
mental disabilities (including children) or those who have not adequate 
experience and knowledge regarding its use, unless they are under the 
supervision of a person responsible for the safety of the appliance. 

 

It is a requirement that installation of the hood must provide minimum distance of 
65cm between the bottom surface of the hood and any electric cook top and 
75cm between any gas ranges or cookers burning other fuels. 

 

Output air must be ducted unique to this product, do not connect to shared air 
ducts. 

 

 

Summary of Contents for CH601SS

Page 1: ...1 Instruction Manual 60cm Chimney Cooker Hood CH601SS...

Page 2: ...2...

Page 3: ...WASHER 13 5 3 WASHING YOUR FILTER BY HAND 13 6 APPLIANCE POSITIONING 14 6 1 INSTALLATION PLAN 14 6 2 UNPACKING THE APPLIANCE 15 6 3 ENERGY SAVING AND EFFICIENT USE 15 7 PACKAGE CONTENTS 16 7 1 OVERVIE...

Page 4: ...ss on these instructions too Disregarding the information in these instructions could result in severe injuries or harm The information in these instructions will ensure best practice in using your ne...

Page 5: ...ation is complete Make sure that the installation method allows a user to easily unplug the power cable in case of a need to isolate the unit Do not touch the lamps when they are in use as they can ge...

Page 6: ...be hermetical When connecting a flue to your product use ducting pipes with a diameter of 150mm or 120mm Minimise both the length and number of connections to the outside to promote good flow and impr...

Page 7: ...2 Fig 2 Poisoning Danger Therefore it is imperative adequate fresh air ingress is confirmed Fig 3 Fig 3 DANGER Warning Choking Hazard The packaging materials are dangerous for children Never allow ch...

Page 8: ...operate two or more gas zones longer than 15 minutes on a high flame setting A large burner over 5kW Wok has the power of two gas burners WARNING Electrocution hazard Never use a malfunctioning elect...

Page 9: ...off the unit isolate or remove the 13a plug from the socket before removing the spent bulb leave bulbs to cool down first Ensure the replacement bulb is of the same type and values CAUTION Surfaces a...

Page 10: ...kitchen Fig 5 Fig 5 Air Circulation with Carbon Filter You can use this appliance in extracted air mode or recirculated air mode NOTICE Exhaust air must not be sent via an active smoke or waste gas fl...

Page 11: ...s central motor assembly by placing the concave side towards the motor 4 One carbon filter at a time offer the filter up to its housing and rotate the filter clockwise Ensure that it is snugly fitted...

Page 12: ...Clean the metal grease filters regularly depending on usage The metal grease filters are designed to capture the greasy particles in the moisture and vapours generated when cooking It is recommended...

Page 13: ...HWASHER It is possible to wash the metal grease filter in a dishwasher This can be very effective but could lead to a slight discoloration of the aluminium over time This has no effect on the function...

Page 14: ...ceed the minimum required distance Fig 8 The minimum distance between the bottom of the hood and a gas or other burning fuel cook top is 75cm The minimum distance between the bottom of the hood and an...

Page 15: ...ng Keep your hood clean especially the aluminium grease filters to ensure efficient air flow Dirty filters can also contribute as a fire risk Ensure you have adequate inlet fresh air into your room so...

Page 16: ...ood Assembly 2 Chimney Extension 3 Chimney 4 Chimney Bracket 5 Operation Manual 6 6mm Wall Plug 7 10mm Wall Plug 8 5 5x60 Wall Mounting Screw 9 3 9x22 Chimney Bracket Screw 10 3 5x9 5 Chimney Screw 11...

Page 17: ...17 7 1 OVERVIEW OF YOUR COOKER HOOD 1 Chimney Extension 2 Chimney 3 Hood Assembly 4 Lighting 5 Aluminium Grease Filter 6 Control Panel Fig 11...

Page 18: ...e to your hood when not in use They comprise of two semi circular plastic flaps that are pushed open by escaping air when you turn on your hood Once fitted the plastic pins tabs on the flaps point upw...

Page 19: ...Wall Plug Mounting the hood 1 Plan where you want to mount your hood in conjunction with the installation plan Fig 9 Make sure you adhere to the minimum height requirement from electric or gas cook to...

Page 20: ...cket at the upmost point of where the chimney is to be sited Your hood is provided with a chimney extension that slides up and down to provide a total height from the bottom of your hood to the top of...

Page 21: ...21 9 OPERATING YOUR PRODUCT How to use the push button controls Fig 15 Push buttons Off Fan speed 1 Fan speed 2 Fan speed 3 Light on and off...

Page 22: ...lamp To replace the bulb 1 Remove the aluminium grease filter 2 Remove the faulty bulb and replace with a new one with the same rating Fig 16 Fig 16 Lamp Replacement WARNING Disconnect the electrical...

Page 23: ...contact Altimo Customer Care Troubleshooting Fault description Problem area to check Remedy Product does not work Check the power connection Mains voltage must be 220 240v and plugged into an earth g...

Page 24: ...rectives This device complies with the Directive on the Control of Waste Electrical and Electronic Equipment Specifications of the device and this manual may be modified without prior notification 13...

Page 25: ...www altimo co uk For customer service call 0330 041 7490...

Reviews: