Figure 4-7: PLL Component Scan Chain Order
DATAIN
C1
C2
C3
C4
DATAOUT
MSB
LF
CP
LSB
N
M
C0
Figure 4-8: PLL Post-Scale Counter Scan Chain Bit Order
DATAIN
rbypass
HB
7
HB
6
HB
5
HB
4
HB
3
HB
2
HB
1
HB
0
rselodd
LB
7
LB
6
LB
5
LB
4
LB
3
LB
2
LB
1
LB
0
DATAOUT
HB
9
HB
8
LB
9
LB
8
Charge Pump and Loop Filter
You can reconfigure the following settings to update the PLL bandwidth in real time:
• Charge pump (I
CP
)
• Loop filter resistor (R)
• Loop filter capacitor (C)
Table 4-2: Charge Pump Bit Control
CP[2]
CP[1]
CP[0]
Setting (Decimal)
0
0
0
0
0
0
1
1
0
1
1
3
1
1
1
7
Table 4-3: Loop Filter Resistor Value Control
LFR[4]
LFR[3]
LFR[2]
LFR[1]
LFR[0]
Setting (Decimal)
0
0
0
0
0
0
0
0
0
1
1
3
0
0
1
0
0
4
0
1
0
0
0
8
1
0
0
0
0
16
1
0
0
1
1
19
UG-M10CLKPLL
2015.06.12
Charge Pump and Loop Filter
4-13
MAX 10 Clocking and PLL Implementation Guides
Altera Corporation
Send Feedback