ALTER PM 740 T Technical Note Download Page 6

    

PM 740 T  

page    4  

of 21

                                                                                                                                      File: PM740T_r3eng -  Settembre 2004   -    Manuale per: PM 740 T

PM 740 

PM 740 

    

PM 740 T 

File: PM740T_r3eng -  Settembre 2004 - Manuale per: PM 740 T                                                                                                                                

         

page     5  

of  21 

Environmental conditions

Use:    

 

Indoor use only

Altitude: 

 

tested  up  to  2,000  m    (~6,000  ft)

Temperature: 

 

5°C to 40°C (41°F÷104°F)

Relative Humidity: 

80% for  temperature up   

 

 

 

 

31°C(88°F), decreasing    

 

 

 

 

linearly to 50% RH at  

 

 

 

 

 

40°C (104°F)

Pollution  degree: 

2, complies with the norm  

 

 

 

 

IEC664 

Fuse specifications

The PM740 has 2 fuses installed on the rear panel (refer to the 

drawing on page 4, position 8): both fuses, labelled F1 and F2, 

protect the output line powering the remote head.

Fuse F1 and F2 specs:

- Size, type: 

 

10x38 mm, ceramic cartridge

- Speed action:   

quick (F)

- Rated current:   

6 A

- Rated voltage:   

500 V

For instructions about fuse replacement please refer to related 

paragraph on the next page.

Physical characteristics

Front panel dimensions:         

 

19” x 3HE 

 

 

 

 

 

(482 x 133 mm)

Rack total width:   

 

 

475 mm

Rack total height:   

 

 

133 mm

Rack depth  (without handles): 

 

440 mm

Housing board depth (minimum):     

800 mm

Total weight:     

 

 

20 kg (44 lbs)

Intake air flow:     

 

 

approx 150 m³/h

Equipment maintenance

Cleaning

Cleaning of the air filter:

verify once a month. In case you need to remove dust  

 

then proceed as follow:

 

- remove main line from the unit

 

- remove the cover

 

- use pressurized air from inside to outside    

 

 

for short time: do not exceed or you  

 

 

 

may damage the fan

 

- install the cover and then power-on again.

Summary of Contents for PM 740 T

Page 1: ...PM 740 T SWITCHING POWER GENERATOR WITH PULSED OUTPUT CAPABILITY FOR 2 kW MAGNETRON C W 8 kW PEAK POWER TECHNICAL NOTE Issue September 2004...

Page 2: ...stanza model PM740T xxx PM740T xxxC TM020 xxx0 modello TM020 xxx1 TMA20 xxx0 TMA20 xxx1 Complies with the following norms Soddisfa le seguenti norme EN 61010 1 1994 A2 1996 EN 61010 1993 A2 1995 EN550...

Page 3: ...product or product family EMC emission standard exists it shall take precedence over all aspects of this generic standard The equipment described in this manual has been classified as industrial scien...

Page 4: ...see drawing a main switch 1 abacklitLCDdisplayshowingaselectedworkingparameter 2 i e one of the following the output power the forward microwave power the reflected microwave power as well as any of...

Page 5: ...tage cat II according IEC 664 Intake current 400 V 7 A max Power factor CW 0 74 Efficiency CW 90 Max Output power 2800 W Max anodic mean current 700 mA CW mode Max anodic peak current 3 1 A Pulse mode...

Page 6: ...pecs Size type 10x38 mm ceramic cartridge Speed action quick F Rated current 6 A Rated voltage 500 V For instructions about fuse replacement please refer to related paragraph on the next page Physical...

Page 7: ...150 m h the outlet of the exhaust air is on the back of the equip ment When designing a cabinet to house several units we recom mend that the following design criteria be adopted use a standard 19 wi...

Page 8: ...asy reach of the operator XII the external circuit breaker must be marked as the discon necting device for the PM740 XIII the connector 1 must never be used as a switch off device Failure to comply wi...

Page 9: ...n this state the output power and the filament is immediately shut off The alarm type is indicated on the display The unit will exit the Alarm mode and enter the Reset Wai ting state only when the ala...

Page 10: ...on the next page then read the specific instruction for every parameter INFORMATION 1 3 Magnetron This indicates how many working hours the magnetron has operated it can be reset by the user from the...

Page 11: ...up Information 1 3 Information 2 3 Information 3 3 OK On Pre v OK On Next Unit Setup 2 2 Press Esc Press Esc Press Esc Press Esc Esc OK On Next OK On Pre v Press Esc OK on Host Com OK on Unit Setup OK...

Page 12: ...ee the comunication protocol documentation Max Rev Pwr This parameter allows the user to set a maximim reverse power threshold If the reverse power input voltage exceeds this threshold the unit will g...

Page 13: ...gnal must be OFF II Connect the serial cable to PC serial port and to RS232 serial port on the PM740 III Remove the top cover of the PM740 IV Locate the CPU board installed on the front panel and set...

Page 14: ...PM 740 PM 740 PM 740 T File PM740T_r3eng Settembre 2004 Manuale per PM 740 T page 13 of 21 COMPONENT LAYOUT bottom layer COMPONENT LAYOUT top layer...

Page 15: ...filter FL20AY01 17 4 Capacitor CR951A2K5 18 1 H V Socket Lemo MOERAY 410 Conn 3 1 H V Plug Lemo MOFFA1Y 410 19 1 Interface board M293 800000293 20 1 14 pin Socket AMP CPC MOCPC14 1826411 Conn 2 21 1 1...

Page 16: ...PM 740 PM 740 PM 740 T File PM740T_r3eng Settembre 2004 Manuale per PM 740 T page 15 of 21 Pin out of CONN 1...

Page 17: ...PM 740 T page 16 of 21 File PM740T_r3eng Settembre 2004 Manuale per PM 740 T Pin out of CONN 2 3 4...

Page 18: ...PM 740 PM 740 PM 740 T File PM740T_r3eng Settembre 2004 Manuale per PM 740 T page 17 of 21 Pin out of CONN 5...

Page 19: ...PM 740 T page 18 of 21 File PM740T_r3eng Settembre 2004 Manuale per PM 740 T Pin out of serial port...

Page 20: ...ected usually due by a sudden drop of the main line voltage check the main supply line or HV cable disconnected VOLTAGE ALARM 4 Overvoltage detected The output voltage exceeds the maximum allowed volt...

Page 21: ...Check the threshold or adjust the power setting INT RAM ALARM 12 Internal memory corruption With the unit switched OFF check that the battery is properly located it s a click in battery installed over...

Page 22: ...solator with dummy load several models available ask for quote and type Cable set p n 44 1384 740 Includes high vol tage cable main line cables head cables signals cable and plugs on psu side p n 44 1...