RI820246 - 06/18 Ind A
39
7.Pressure lost or iron in
conditioned water.
A. Iron in the water supply pipe.
B. Iron mass in the softener.
C. Fouled resin bed.
D. Too much iron in the raw
water.
A. Clean the water supply pipe.
B. Clean valve and add resin cleaning chemical,
increase frequency of regeneration.
C. Check backwash, brine draw and brine tank refill.
Increase frequency of regeneration and backwash
time.
D. Iron removal equipment is required to install
before softening.
8.Loss of resin through
drain line.
A. Air in water system.
B. Bottom strainer broken.
C. Improperly sized drain line
control.
A. Assure that well system has proper air eliminator
control.
B. Replace the bottom strainer.
C. Check for proper drain rate.
9.Control cycle
continuously.
A. Controller is faulty.
B. Time of regeneration steps
were set to zero
C. Locating signal wiring break-
down
D. Foreign material stuck the
driving gear.
A. Replace the controller.
B. Check program setting and reset.
C. Check and connect locating signal wiring.
D. Take out foreign material.
10.Drain flows
continuously.
A. Internal valve leak.
B. When electricity fails to
supply, valve stops backwash or
fast rinse position.
C. Control valve is in Backwash
status.
A. Check and repair valve body or replace it.
B. Adjust valve to service position or turn off bypass
valve and restart when electricity supply.
11.Salt water in soften
water.
A. Foreign material in injector or
injector fails to work.
B. Brine valve cannot be shut-off.
C. Time of rapid rinse too short.
A. Clean and repair injector.
B. Repair brine valve and clean it.
C. Extend rapid rinse time.
12.Interupted or
irregular brine.
A. Water pressure too low or not
stable.
B. Injector is plugged or faulty.
C. Air in resin tank.
D. Floccules in resin tank during
backwash.
A. Increase water pressure.
B. Clean or replace injector.
C. Check and find the reason.
D. Clean the floccules in resin tank.
Summary of Contents for 6997865
Page 3: ...Altech 2 3 4 5 6 7 6 7 8 I CONDITIONSETCARTEAN 35 6 10 11...
Page 13: ...Altech 12 pr r gl en usine pr r gl en usine...
Page 15: ...Altech 14 f r gler l installation...
Page 18: ...RI820246 06 18 Ind A 17 M f f f Vis de r glage du Mixing...
Page 24: ...RI820246 06 18 Ind A 23 2 2 2 3 3 D CONDITIONS 37 I 8 24 2 9 29 3 30 9 3 5 7 7 5 8...
Page 31: ...Altech 30 set installation set in factory...
Page 32: ...RI820246 06 18 Ind A 31 set in factory set in factory...
Page 33: ...Altech 32 set in factory...
Page 34: ...RI820246 06 18 Ind A 33 Primeo 18 L 1 00 23 00 3 20 3 00 f set installation...
Page 37: ...Altech 36 f f f Mixing adjustment screw...
Page 38: ...RI820246 06 18 Ind A 37 f...
Page 49: ...Notes...
Page 50: ...Notes...