Commissioning
GB
HZ1/Pump
HZ2
HZ3
HZ4
1
2
1
2
N
L
1
2
T6.3AH
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
HZ5
HZ6
HZ7
HZ8
HZ9
HZ10
Relay HZ2 - HZ10: 230V / 50Hz / 1A / max. 24W
Relay HZ1 230 V ~ 3 (1) A
230 V
The pump control is activated or deactivated directly at the base station, or with an Altech V3 IP room
control unit Display.
6.4.1 Activation/deactivation of the pump control (base station)
1. Press and hold the Select key (B) of the Altech V3 IP base station approximately for 4 seconds, until
the LED of heating zone 1 flashes in green:
2. Toggling the pump from active to inactive or vice versa: Press the Select key (B) for 4 seconds.
3. Leaving the menu without changes: Press the Select key shortly.
6.4.2 Activation/deactivation of the pump control (Room control unit Display)
With the Altech V3 IP room control unit Display, different parameters can be assigned to the pump
control. For this, the parameter P025 in menu UnP1 (see section 8: Configuration) must be changed
according to the requirements.
For parametrisation, one Altech V3 IP room control unit must have been taught in to heating
zone 1. This device can be used for further heating zones.
7 Commissioning
For the commissioning of the Altech V3 IP base station, at least one Altech V3 IP room control unit
Display or Analog must be taught-in to the base station. As an alternative, the base station can be inte-
grated to the Altech V3 IP Access Point via the app into the Altech V3 IP system. If used without Access
Point, the base station must be configured via the Altech V3 IP room control unit Display.
1. Establish the electrical supply of the Altech V3 IP base station.
9
All heating zones of the base station are activated for 10 minutes in order to unlock the first-open
function of connected actuators.
9
A 2-point regulation is performed in the first 30 minutes after the initial voltage supply.
2. Proceed with section 7.1 or 7.2 depending on the system configuration.
Display
Meaning
0
0,1
0,2
0,3
0,4
HZ1
Duration in seconds
Pump inactive
(UnP1: P025, value 4)
0
0,5 1,0
1,5
2,0
HZ1
Duration in seconds
Pump active
(UnP1: P025, value 0)