1301 Series High-Pressure Regulators
!
WARNING
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion,
fire and/or chemical contamination
causing property damage and personal
injury or death.
Fisher
®
regulators must be installed,
operated and maintained in accordance
with federal, state and local codes, rules
and regulations and Fisher instructions.
If the regulator vents gas or a leak
develops in the system, service to the unit
may be required. Failure to correct trouble
could result in a hazardous condition.
Installation, operation and maintenance
procedures performed by unqualified
personnel may result in improper
adjustment and unsafe operation. Either
condition may result in equipment
damage or personal injury. Use qualified
personnel when installing, operating
and maintaining the 1301 Series high-
pressure regulator.
Introduction
Scope of the Manual
This Instruction Manual provides instructions for the
installation, adjustment, maintenance and parts ordering
of the Types 1301F and 1301G high-pressure regulators.
Product Description
Types 1301F and 1301G regulators are direct-operated,
high-pressure regulators, which can be used where
high-pressure gas must be reduced for use as pilot
supply pressure in pilot-operated regulators or as
loading pressure in pressure-loaded regulators.
Figure 1.
Type 1301F High-Pressure Regulator
Types 1301F and 1301G regulators can also be used
in many other applications due to their rugged design
as high-pressure reducing regulators for various fluids
such as air, gas, water and other liquids.
The Type 1301F can handle outlet pressures from 10 to
225 psig / 0.69 to 15.5 bar in three ranges and the
Type 1301G can handle outlet pressures from 200 to
500 psig / 13.8 to 34.5 bar in one range.