Use precautions:
-
The machine must be used by one person at a time.
-
During loading, the machine must be stopped in the loading position.
-
The machine must be made solid with the dock or building throughout the loading time.
-
The hydraulic unit must be stopped, if loading is carried out by means other than the loader arm
(see descriptive diagram).
-
Follow the implementation conditions for the rails and electrical connections, all these operations
must be carried out by a professional.
-
Adjust rotation speed with valves located nearby hydraulic motor and tight screw without head.
Maintenance:
-
Grease the joints regularly
-
On each use check the good condition of the screws and pins. In particular check the support
fixing screws of the belt and guards.
-
Regularly check the oil level of the hydraulic system. Fill up with oil HV46 as required. The first oil
change is carried out after
500 hours
with exchange of the immersed 10-micron return filter.
After that, change the oil every
1000 hours
of use.
Tank capacity: 50 l
ANY DEFECTIVE PART MUST BE REPLACED. THE SCREWS, CLIPS AND PINS
MUST NOT BE REPLACED WITH OTHER THINGS.
Electrical connection
Three-phase + earth
3 x 400V 20A
Electrical connection
of limit switch contacts
according to diagram