ARCHITECTS & ENGINEERS SPECIFICATION

The transformers shall be Altec Lansing Professional model numbers T560-71 and T5100-71, rated at 60 Watts and 100 Watts, respectively.
Their frequency response shall be 35 Hz to 15,000 Hz, ±0.5 dB. Throughout their 35 Hz to 15,000 Hz bandwidth, at rated power, they shall
produce no more than 0.5% T.H.D., and their insertion loss shall not exceed 1 dB. These transformers shall require no more than 10%
above their rated input power to deliver rated power to the load at 35 Hz. The T560-71 and T5100-71 shall provide true electrical
isolation to the source and to the load. Connection to these transformers shall be through 0.25-inch blade type wire terminals. The
nominal primary taps shall be 4 ohm and 8 ohm, and the nominal secondary taps shall be 70.7V and 100V.round white metal grille.

E

E5475 REV01

© 2002 Altec Lansing Professional

1000 W. Wilshire Blvd., Suite 362
Oklahoma City, Oklahoma 73116

Phone: 1-405-848-3108 • Fax:  1-405-848-3217

Web: www.altecpro.com • Email:  [email protected]

P R O F E S S I O N A l

T560-71
T5100-71

4 Ohm 
to 70 V

1:4.5
1:3.5

4 Ohm 
to 100 V

1:6.4
1:5.0

8 Ohm 
to 70 V

1:3.2
1:2.5

8 Ohm
to 100 V

1:4.6
1:3.5

4/8 term
to 70 V

1:10.9
1:8.5

4/8 term
to 100 V

1:15.4
1:12.0

voltage ratio

T560-71
T5100-71

4 Ohm
to 70 V

1:20.8
1:12.5

4 Ohm 
to 100 V

1:41.7
1:25.0

8 Ohm
to 70 V

1:10.4
1:6.3

8 Ohm
to 100 V

1:20.8
1:12.5

4/8 term
to 70 V

1:21.9
1:13.1

4/8 term
to 100 V

1:44.0
1:27.0

impedance ratio

wiring diagram

COMMON

COMMON

70.7 V

100 V