ALTEC AIR, LLC
P1500W Series Air Dryers User’s Guide
Page 72 of 101
P011787 – Rev. R
Models).
9.15.4
Turn knob counter-clockwise until Outlet Pressure (
OUTP
) reading drops
below:
6.5 PSI
for P1500W & P1502W models
0.30 PSI
for P1500WLP& P1502WLP models
25.0 PSI
for P1500WHP & P1502WHP models
After one (1) minute, the Low Pressure Alarm should appear on the display.
9.15.5
Turn Outlet Pressure
Regulator knob clockwise
until Outlet Pressure (
OUTP
)
reading rises to the reading
recorded in step 9.15.1
9.15.6
Push knob in to lock (or tighten the retaining nut – LP Models).
9.15.7
Press the
RESET
Button
.
9.15.8
Close Front Panel.
If you are unable to create a Low Outlet Pressure Alarm as described, see section
13.8 for troubleshooting information.