LAST RUN
) alarm should appear on the System Screen.
9.12.4
Press the
RESET Button
.
9.12.5
Close Front Panel.
If you are unable to create a High Compressor Last Run Time (LAST RUN)
alarm as described, see section 13.18 for troubleshooting information.
9.13 Testing Humidity Alarm and System Shutdown
9.13.1
Power the air dryer
OFF
.
9.13.2
Open Front Panel
(section 8.6 ).
9.13.3
Depressurize the air dryer.
9.13.4
Unscrew and remove the
Humidity Sensor from the
Humidity Block.