MTX-416 - PROGRAMMABLE 4x16 INTERCOM MATRIX

 

 
One of the five LED associated to the switches, remains lighting, indicating the memory in 

which it is located the unit. If the working memory and the stored memory are the same, the LED 
will remain without blinking, and if the working memory and the stored memory are different, the 
LED will be blinking. 

By means of these five keys it is possible to be acceded of direct mode to the five stored 

memories, always considering that when recovering a stored memory, the working memory will 
be lost. 

Mediante estas cinco teclas se puede acceder de manera directa a las cinco memorias 

almacenadas, siempre teniendo en cuenta que al recobrar una memoria guardada, la memoria 
de trabajo se perderá. 

It exists a memories bank for the NORMAL mode and other for the REVERSE mode, reason 

why five memories for each mode can be recorded. 

When acceding to a determined memory, if the system were linked with other MTX-416 units, 

they will change all the connected units, to the memory number to which we have acceded. 

 

MEMORY STORE SWITCH 

 

The store switch allows us to record the working memory on anyone of the five 

memories (M1-M5) available in the system. 

When pressing the STORE switch, display will indicate 

M1-5 blinking, the five leds of the direct memory recall 
switches will begin to blink, as well as the LED 
corresponding to the STORE switch, being indicated that we 
are in recording mode. 

The unit reset the recording mode if we do nothing or press a switch other than STORE, M1 — 

M5, in a few seconds. 

If we pressed one of the direct memory recall switches (M1-M5), the working memory will be 

recorded in the memory number corresponding to the pressed key. 

When the memory is recorded, the unit change to the memory number on which we have 

recorded the working memory, reason why if the system were linked with other MTX-416 units, all 
the connected units will change to the memory number on which the working memory has been 
recorded. 

 

MEMORY PREVIEW SWITCH  

 

With this PREVIEW switch we can see the memories recorded directly in display  
When pressing the PREVIEW switch, display will indicate M1-5 blinking, the five leds 

of the direct memory recall switches will begin to blink, as 
well as the LED corresponding to the PREVIEW switch, being 
indicated that we are in preview mode. 

The unit reset the preview mode if we do nothing or 

press a switch other than STORE, M1 — M5, in a few 
seconds. 

If we pressed one of the direct memory recall switches (M1-M5), the corresponding memory 

will appear in the display blinking, as well as it will continue blinking the PREVIEW switch. Passed a 
few seconds, the system will return to normal mode. 

 
 
 

Summary of Contents for MTX-416

Page 1: ...UDIOELECTRONICSDESIGN AUDIOELECTRONICSDESIGN AUDIOELECTRONICSDESIGN AUDIOELECTRONICSDESIGN EQUIPOS EUROPEOS ELECTR NICOS S A L Avda de la Industria 50 28760 TRES CANTOS MADRID SPAIN 34 91 761 65 80 34...

Page 2: ...ERCOM AUDIO LINES CONNECTION 8 SYSTEM EXPANSION 9 COMPUTER CONNECTION 13 5 OPERATION 13 DISPLAY 14 DIRECT MEMORY RECALL SWITCHES M1 M5 14 MEMORY STORE SWITCH 15 MEMORY PREVIEW SWITCH 15 MEMORY CLEAR S...

Page 3: ...ted lines The design incorporates input and output link connectors for easy X and Y expansion of number of channels and or lines An 8 channels to 32 lines matrix system can be done with 4 units The us...

Page 4: ...and connectors that you can find in your ALTAIR matrix The description and explanation of each one will be found in the corresponding section FRONT PANEL DISPLAY NAVIGATION SWITCHES UP DOWN LEFT RIGHT...

Page 5: ...TOR FOR COMPUTER CONTROL PHOENIX TM CONNECTORS TO CONNECT CONECTORES FCC 68 DE ENCADENAMIENTO THE INTERCOM LINES L1 L16 DE UNIDADES IDC CONNECTOR FOR LINE EXPANSION IDC CONNECTOR FOR CHANNEL EXPANSION...

Page 6: ...lified service technician Do not place the unit close to heat sources 4 INSTALLATION UNPACKING Before leaving the factory each intercom matrix has been carefully inspected and tested Unpack and inspec...

Page 7: ...supply male connector placed at the rear panel Insert the male connector of the tripolar cable into the mains plug Turn on the unit power switch In that moment all the leds of the unit will light sli...

Page 8: ...1 CH4 REVERSE MODE 16 IN 4 OUT INTERCOM AUDIO LINES CONNECTION If the ALTAIR MTX 416 unit is used like intercom matrix we will connect the intercom lines L1 L16 to a unit with intercom passive channel...

Page 9: ...all the intermediate situations Altogether we can link four units if we want to increase the line number we will link the units by means of the EXPANSION Y connector and if we want to increase the num...

Page 10: ...10 MTX 416 PROGRAMMABLE 4x16 INTERCOM MATRIX 12x16 MATRIX 16x16 MATRIX...

Page 11: ...11 MTX 416 PROGRAMMABLE 4x16 INTERCOM MATRIX 4x32 MATRIX 4x48 MATRIX...

Page 12: ...12 MTX 416 PROGRAMMABLE 4x16 INTERCOM MATRIX 4x64 MATRIX 8x32 MATRIX...

Page 13: ...rtical and exclusive mode so any intercom equipment connected to line 1 for example can be addressed exclusively to one of the 4 channels Power to the lines is taken from the 4 intercom channels and d...

Page 14: ...we will select each channel to that line we want to connect it If we waited for a time without doing anything the edition mode will be reset and the LED will let blink If we pressed a switch that is n...

Page 15: ...indicate M1 5 blinking the five leds of the direct memory recall switches will begin to blink as well as the LED corresponding to the STORE switch being indicated that we are in recording mode The un...

Page 16: ...cted to one of the sixteen lines IN When pressing the REVERSE switch the display will indicate YES blinking as well as the LED corresponding to the REVERSE switch indicating that we are in reverse mod...

Page 17: ...JP5 for the channel 3 and JP6 for the channel 4 placed at the left part of the main PCB near the rear panel looking at the unit from the front panel With the jumper placed the terminal impedance will...

Page 18: ...18 MTX 416 PROGRAMMABLE 4x16 INTERCOM MATRIX 8 BLOCK DIAGRAM...

Page 19: ...ns of the ALTAIR MTX 416 matrix reason why we have an open and flexible system being able to control remotely by means of matrix MTX 416 the configuration of the intercom lines in real time If we adde...

Page 20: ...RECOMMENDED WIRE TYPE Shielded mic cable 2 x 0 30 mm2 CONNECTIONS 1 NO 1 NC circuit JACK RELAYS CONTACTS 0 5 Amp 125 VAC 1 Amp 30 VDC MAINS VOLTAGE 90 264 VAC 50 60 Hz POWER SUPPLY 12 VDC nominal 1 8...

Page 21: ...nty expressed or implicit Any faulty unit must be sent to the dealer or the manufacturer The serial number of the unit must be included for any request to the technical service Equipos Europeos Electr...

Page 22: ...nicos RAEE El logotipo de la Directiva RAEE se refiere a los programas y procedimientos espec ficos de reciclaje para aparatos electr nicos de pa ses de la Uni n Europea Recomendamos el reciclaje de...

Reviews: