E32.0.A3.6C-01 Manual for connection and operation of the JDS-211 page 6 of 16
4. General notes to the operating of the menu
By means of
button 1
you can go to the next parameter
.
Additionally a given changing in the parameter setting can be con-
firmed by this button and the new value will be saved. Afterwards it
will be changed to the parameter view again
By means of
button 2
or
button 3
you can go from the parameter
view to the parameter setting and adjust its value there.
Hint:
The buttons 2 and 3 are featured with a ‘roll-function‘. When pressing the button once the value will be raised
(button 2) by one or lowered (button 3) by one. When holding the button pressed for longer than 1 sec. the
value starts counting up or down, the counting speed will be raised after a short period of time.
The device also features a ‘overflow-function‘, when reaching the upper limit of the range, the device switches
to the lower limit, vice versa.
By means of
button 4
a
given changing will be cancelled in the parameter setting. The changing will be
discarded and the former parameter value will be preserved.
In the parameter view button 4 closes the menu.
Please note:
If you don’t press any button for more than 10 sec. in the parameter setting, the adjustment will
be cancelled, the changing discarded and it will be changed to the parameter view. If you don’t
press any button for more than 60 sec. in the menu, the menu will be automatically closed.
5. Configuration
5.1. Output function
- Turn the device on and wait until it completed its built-in segment test.
- At the same time press the pushbutton on the rear side (button 5) and button 1 for >2 seconds.
- The device displays “
outP
“ ('output').
- Use
button
2 or button 3 to select the output function.
- Press
button
1 to validate the selected output function. The display shows “
outP
“ again.
- According to the selected output function further adjustments (see table below) have to be done.
“
outP
“
Output function.
According to the selection the outputs will be allocated as the following table shows.
Description
To select
as output
Output 1
(make contact)
Output 2
(change-over
contact)
See chapter
No output, device is
used as display unit
no
off
off
--
2-point-controller
2P
PID switching func-
tion
motorised valve
control open
off
motorised valve
control close
5.1.1
3-point-controller
3P
PID switching func-
tion
switching function 2
5.1.1
2-point-controller with
Min-/Max-alarm
2P.AL
PID switching func-
tion
Min-/Max-alarm,
inverse
5.1.1
Min-/Max-alarm,
common
AL.F1
off
Min-/Max-alarm,
inverse
5.1.2
Min-/Max-alarm,
individual
AL.F2
Min-/Max-alarm,
inverse
Min-/Max-alarm,
inverse
5.1.2
SET
1
2
3
4
SET
Cal
T
SP/Tn
min.
Xp/Tv
max.
Scale
Analog
Alarm
1