LED INDICATORS
LED (PWR):
Flashes with a 1Hz frequency when the supervision security is active. In case of a supervision
disturbance this LED will flash together with the associated input LED (1-8). If the supervision
security is disabled the LED will illuminate continuously. During the direct learning procedure
(SW 8 = ON) the LED will not illuminate at all.
LED (COM):
Flashes during RS-485 communication with the AlphaVision
LED (RF):
Flashes when it receives a PowerCode signal
LED
(1-8):
Input 1-8 status LED (see table )
Situation
INPUT LED 1-8
96 zone status NG/EC zone status
Zone alarm
LED on
zone alarm
zone alarm
Zone low battery alarm
LED flashes fast
zone sabotage
zone low battery
Zone supervision alarm
LED flashes slow
zone sabotage
zone supervision
Zone sabotage alarm
LED on
zone sabotage
zone sabotage
JUMPERS
CLR:
Is used to delete one input or all inputs during the direct learning method.
See chapter “ERASING ZONES”.
JP5:
For bypassing the tamper switch on the casing.
TESTING
With the Winterm software program you can observe the status and signal strength of the PowerCode detectors and
Code Secure (keyfob) transmitters. We recommend to keep a list of all wireless inputs including zone names, ID
code and signal strength at hand. Activate the ID Code enrolling procedure, See chapter “ID CODE ENROLLING
WITH A LAPTOP OR COMPUTER”. The following will appear on your screen:
Activate the detector or keyfob transmitter. As soon as the signal of the detector or transmitters is received, the
status strength will be appear on your screen in the “rf” column.
When using a keyfob transmitter the status is displayed by using the words “
CLOSE
” of “
OPEN
”:
Installer manual AlphaVision Wireless Interface Rev. 2.0 27-11-2006 Page. 7/8