background image

When you are finished programming, put the dipswitches 1-4 back to the address settings of the RS-485 bus and 
put the slide switches JP2 and JP3 to the AV mode. Finally put dipswitch 8 to OFF. The RS-485 communication 
with the control panel will be restored. 

 
c)  Program the associated names for each wireless keyfob into the zone programming of the control panel and use 

zone TYPE 6 = “keyswitch”, including normally closed (NC) with End of Line (EOL) zone. The top two buttons on 
the MCT-234 can be used to arm and disarm the AlphaVision NG control panel, the bottom two buttons are not 
supported by the wireless interface.  
 
In screen 8 of the Alphavision NG programming set the option “Keyswitch PULS” to the “latch mode” by 
programming a “N”. 

 

!

 

Program the wireless keyfob transmitter into the Alphavision as zone type 6 

“Keyswitch”,

 

Normally 

Closed

  

and

 

with end of line (EOL).

 

 

 

IMPORTANT! 

When a Code Secure keyfob transmitter is used to arm or disarm the Alphavision NG/EC (Alpha 

Easy), we recommend to program only one section. 

Otherwise this can lead to strange situations for the end user. 

 

ERASING INPUTS 

 

a)  Put dipswitch 8 to ON. The communication with the RS-485 bus of the control panel will stop and the ‘learning’ 

mode has been activated. Put the slide switches JP2 and JP3 into the PC mode (RS-232 mode).  

 
b)  If you want to delete an input , select the desired input you want to delete by using dipswitches 1-4 and short-

circuit the 

CLR 

pins for 2 seconds. When the transmitter or detector is deleted from the input you will hear the 

victory melody and the associated input LED will flash. 

 
c)  If you want to delete all inputs at once, you can set-up input 0 through the dipswitches 1-4 and short-circuit the 

CLR jumper for 2 seconds. As confirmation all zones are deleted you will hear the victory melody and all input 
LED’s will flash. 

 
e)  When you are finished programming, put the dipswitches 1-4 back to the address settings of the RS-485 bus and 

put the slide switches JP2 and JP 3 back to the AV mode (RS-485). Finally set dipswitch 8 to OFF. The RS-485 
communication with the control panel will be restored. 

 

ID CODE ENROLLING WITH A LAPTOP OR COMPUTER  

 

a)  Put slide switches JP2 and JP3 in the PC mode (RS-232 mode). Connect the laptop or computer to the wireless 

interface by means of the RS-232 programming cable (art. Code 003834). 

 
b)  Start the Winterm or TermPriv program software. 
 
c)  Set the dipswitches 1 – 8 to 

OFF

.  

 
d) Short-circuit the 

CLR

 jumper for 2 seconds. The set-up menu of the Wireless Interface will appear on your 

computer screen. 

 

After selecting the input you want to program (1-8), you can enter the unique eight digit PowerCode ID code. The 
unique ID code can be found on the sticker of the IC inside of the PowerCode detector. If the code is entered 
correctly, the Wireless Interface will recognize the PowerCode detector. To put this to the test, activate the 
detector and observe if any characters appear in the status bar. When the associated zone name has already 
been programmed into the AlphaVision control panel, the name will show up in the name bar. The zone names 
cannot be altered here, this is merely for support purposes.  
 

 f)  Leave the set-up by putting one of the dipswitches to 

ON

. When you are finished programming use the 

dipswitches 1-4 and set the address settings back to RS-485 bus (See figure 1). Set the slide switches JP2 and 
JP3 back to AV mode (RS-485). Remove the program cable and close the casing.  

 

 

Installer manual AlphaVision Wireless Interface           Rev. 2.0                      27-11-2006                                        Page. 5/8 

 

Summary of Contents for AlphaVision Wireless interface

Page 1: ...Wireless Interface Installation Manual Alphatronics bv Watergoorweg 71 3861MA Nijkerk Tel 033 2459944 Fax 033 2453149 info alphatronics nl...

Page 2: ...ssible to use Code Secure Rolling Code keyfobs to arm or disarm the Alphavision system with a wireless keyfob transmitter This option is only available on the Wireless Interface module revision 2 0 an...

Page 3: ...programmed into the Wireless Interface the dipswitches 1 4 must be set to the address settings of the RS 485 See figure 1 for an overview of these settings Connect the power supply and back up batter...

Page 4: ...etector has been programmed correctly activate it again Each time the detector is activated the victory melody will be heard When the input is already in use you cannot program a new detector to this...

Page 5: ...ough the dipswitches 1 4 and short circuit the CLR jumper for 2 seconds As confirmation all zones are deleted you will hear the victory melody and all input LED s will flash e When you are finished pr...

Page 6: ...or input number See figure 1 Sw 5 ON AlphaVision NG and EC Alpha Easy OFF AlphaVision 96 CP 508LCD Low battery supervision and sabotage are reported as sabotage Sw 6 ON supervision 4 hours OFF superv...

Page 7: ...otage alarm LED on zone sabotage zone sabotage JUMPERS CLR Is used to delete one input or all inputs during the direct learning method See chapter ERASING ZONES JP5 For bypassing the tamper switch on...

Page 8: ...The signal strength for each input is displayed in the column rf as a value between 00 and 200 A signal strength lower than 30 is very weak we advise to change the location of the detector of wireless...