LiftCallLineC
– User guide
51
Parametr Value
Description
Default
54
r
Hanging up time during REDIAL (1-5)
1
z
– time [sec] for which communicator hangs up before pick up for REDIAL
(button push during call, busy tone detection) [range 1-5]
Parametr Value
Description
Default
55
s
Time before start dialling (1-5)
1
z
– time [sec] after communicator picks up and before start dialling [range 1-5].
This time is different for every PBX but usually all PBXs accepts dial within 2
seconds after line is picked up.
Parameter Value
Description
Default
56
e
Time without ringing tone
– call detection (1-0)
5
e
– 1 ÷ 10 sec (0 = 10 sec) is time for which is not detected ringing tone after
dialling of number. If is set at number dial without confirmation then is set that
call started. This parameter significantly determines the correct auto confirmation
call. The aim should be to set the smallest possible value.
Example:
Parameter Value
Description
Default
57
cc
Time waiting for confirmation [sec] (10-99)
25
cc
– 10 ÷ 99 sec is time which after number dialling the BraveLLW waiting for
call confirmation. If to this time call not confirmed (parameters 47-40), so
BraveLLW hangup and pickup and dial next telephone number.
Parametr Value
Description
Default
58
hh
Number of rings before hang up (04-99)
12