2.11 Output and Overload LEDs
Substantial overloading that continuously lights the overload LED (Red) may damage the generator. Marginal
overloading that temporarily lights the overload LED (Red) may shorten the service life of the generator.
CAUTION!
The output indicator light (Green) will remain illuminated during normal operating conditions.
If the generator is overloaded (in excess of 3100 W), or if there is a short in the connected equipment, the
output indicator light (Green) will go out, the overload indicator light (Red) will turn on and current to the
connected equipment will be shut off.
1. Remove all electrical loads from the generator and investigate the cause of the overload.
2.
To reset the overload condition (Red light), stop and restart the generator. The (Green) indicator light
should be illuminated within 10 seconds.
2.0 Operation
•
Before connecting or reconnecting a power supply to the generator, check that it is in good order, and that its
electrical rating does not exceed that of the generator.
• When an electric motor is started, the overload indicator light (Red) may go on momentarily while the output
indicator light (Green) remains on. This is not a problem as long as the overload LED only flickers on briefly.
NOTE:
Circuit Breaker
120V AC 20A
NEUTRAL FLOATING
NEUTRE FLOTTANT
DC 12V 8.3A
SYSTEM FLOATING
SYSTÈME FLOTTANT
OFF
ON
OVERLOAD
RUN
LOW OIL
Overload LED (Red)
Reset Button (GREEN)
Run Light (GREEN)
Figure 2-8, LED Location