Parameter
E-Tec Plus 28
E-Tec Plus 33
‘I’
93
93
‘II’
*
*
‘III’
1.11
95
‘IV’
0.44
0.37
12.6 PARAMETERS FOR FILLING IN ASSEMBLY CHART
* To be established by means of table 5 of Regulation 811/2013 in case of “assembly” including a heat pump to integrate the
boiler. In this case the boiler must be considered as the main appliance of the assembly.
Seasonal space heating energy efficiency of boiler
1
%
Supplementary heat pump
From fiche of heat pump
Solar contribution AND Supplementary heat pump
Select smaller value
Boiler and supplementary heat pump installed with low temperature heat emitters at 35°C?
From fiche of heat pump
The energy efficiency of the package of products provided for in this fiche may not correspond to its
actual energy efficiency once installed in a building, as the efficiency is influenced by further factors
such as heat loss in the distribution system and the dimensioning of the products in relation to building
size and characteristics.
Seasonal space heating energy efficiency of package
Seasonal space heating energy efficiency class of package
Solar contribution
From fiche of solar device
2
%
+
3
%
±
( - ______ ) x 0,1 =
( - _____ ) x _______ =
0.5 x O 0.5 x =
4
5
6
7
4
5
%
%
%
%
+
+
-
Collector size
(in m
2
)
Tank volume
(in m
3
)
Collector efficiency
(in %)
Tank rating
A* = 0.95, A = 0.91
B = 0.86, C = 0.83
D-G = 0.81
( ____ x + ____ x ) x (0,9 x ( / 100) x =
G
F
E
D
C
B
A
A
+++
A
++
A
+
< 30 %
≥ 30 % ≥ 34 % ≥ 36 % ≥ 75 % ≥ 82 % ≥ 90 % ≥ 98 % ≥ 125 %≥ 150 %
%
7
+ ( 50 x ______ ) =
____
12.5 ROOM HEATING SYSTEM ASSEMBLY CHART
Class I = 1 %, Class II = 2 %,
Class III = 1.5 %, Class IV = 2 %,
Class V = 3 %, Class VI = 4 %,
Class VII = 3.5 %, Class VIII = 5 %
Temperature control
From fiche of temperature
control
Supplementary boiler
From fiche of boiler
Seasonal space heating energy afficiency
(in %)
Seasonal space heating energy afficiency
(in %)
Alpha E-Tec Plus 28 and 33 - Energy Classification