background image

Fig. 8

Note: 

The equivalent horizontal flue assembly the equivalent plume management length (PM length) must not

exceed the maximum flue length stated for each boiler, i.e.

Alpha CD boiler maximum equivalent flue length must not exceed 12 metres.

Alpha HE boiler maximum equivalent flue length must not exceed 3 metres.

Note:

1. Ensure each joint is

secured with the screw
supplied.

2. Ensure there is always

a slight slope towards
the CD Easy-Flue so
that there is no part of
the pipework where
condensate will collect.

Leaflet compiled and designed by Publications 2000, Tel (01670) 356211

04/09/D232

These instructions have been carefully prepared but we reserve the right to
alter the specification at any time in the interest of product improvement.
© Alpha Therm Limited 2009.

Alpha Therm Limited.
Nepicar House, London Road, Wrotham Heath,
Sevenoaks, Kent  TN15 7RS
Tel: 0870 3001964

email: [email protected]
website: www.alpha-innovation.co.uk

Reviews: