Fig. 8
Note:
The equivalent horizontal flue assembly the equivalent plume management length (PM length) must not
exceed the maximum flue length stated for each boiler, i.e.
Alpha CD boiler maximum equivalent flue length must not exceed 12 metres.
Alpha HE boiler maximum equivalent flue length must not exceed 3 metres.
Note:
1. Ensure each joint is
secured with the screw
supplied.
2. Ensure there is always
a slight slope towards
the CD Easy-Flue so
that there is no part of
the pipework where
condensate will collect.