background image

0300189-J1  Rev B

22

Figure 14  —  CAN Connection

5�4�3  Making CAN Connection

The shelf can be connected to an Alpha controller (CXCI+) via CAN. For CAN connection, refer to the drawings at the 
end of this manual (0300189-08). 
For detailed information on the CXCI+ operation in the system, refer to the system manual 0120011-J1, available on 
the Alpha website.

SCALE:

REV

SHEET

SIZE DWG NO.

TITLE:

OF

A

1:2

B

1 1

0300189-08

CUSTOMER CONNECTIONS, 

LPS 36 COMPACT SHELF

THESE DESIGNS AND SPECIFICATIONS ARE
CONFIDENTIAL, REMAIN THE PROPERTY OF

ALPHA TECHNOLOGIES LTD., AND SHALL NOT BE

COPIED OR USED WITHOUT ITS WRITTEN CONSENT

© ALPHA TECHNOLOGIES LTD

CHECKED

DRAWN

DATE

APPROVALS

G. LUMANOG

May-29-15
May-29-15

K.LAU

THIRD ANGLE PROJECTION

UNLESS OTHERWISE SPECIFIED

DIM ARE IN MM

INTERPRET DIM AND TOL  PER

ASME Y14.5M-1994

X

X.X

X.XX

ANGULAR:

1

1

0.5

0.25

REFER TO NAMEPLATE FOR INPUT/OUTPUT VOLTAGE AND CURRENT RATEINGS.

1.

NOTES UNLESS OTHERWISE SPECIFIED:

REFER TO BUBBLE NUMBER 

IN BILL OF MATERIALS.

ITEM

GROUND TERMINAL

1/4" STUD 5/8" CENTER TO CENTER

TORQUE TO 12 NM (105 in-lb)

FOR CONNECTING TO 

FAN TRAY (IF USED)

OUTPUT CONNECTOR

50 POSITIONS, CHAMP-LOK

SEE OUTPUT CONNECTIONS TABLE

INPUT CONNECTIONS

1/4" HOLE 5/8" CENTER TO

CENTER LUG, SEE LABEL 

ON WIRE FOR POLARITY

ALARM CONNECTION CABLE,

9 CONDUCTORS, AWG#22, 

SEE ALARM CONNECTIONS TABLE,

FORM C CONTACTS, MAX CURRENT 1A, 60V

CAN BUS

CONNECTOR

MODULAR JACK

6P6C

SEE CAN BUS TABLE

LPS36 MODULE

MAXIMUM 4 MODULES

SCREWS SECURING THE GROUND

TERMINAL PLATE, UNDO SCREWS TO

MOVE GROUND TERMINAL TO THE 

OTHER SIDE.

REVISIONS

LTR

DESCRIPTION

DWN

DATE

CHK

A

INITIAL RELEASE

KLAU May-29-15

GL

OUTPUT CONNECTIONS

PIN#

MODULE

CHANNEL

PIN#

MODULE

CHANNEL 

1

1

CH1_-190V

26

1

CH1_+190V

2

CH2_-190V

27

CH2_+190V

3

CH3_-190V

28

CH3_+190V

4

CH4_-190V

29

CH4_+190V

5

2

CH1_-190V

30

2

CH1_+190V

6

CH2_-190V

31

CH2_+190V

7

CH3_-190V

32

CH3_+190V

8

CH4_-190V

33

CH4_+190V

9

3

CH1_-190V

34

3

CH1_+190V

10

CH2_-190V

35

CH2_+190V

11

CH3_-190V

36

CH3_+190V

12

CH4_-190V

37

CH4_+190V

13

4

CH1_-190V

38

4

CH1_+190V

14

CH2_-190V

39

CH2_+190V

15

CH3_-190V

40

CH3_+190V

16

CH4_-190V

41

CH4_+190V

17

N/C

42

N/C

18

N/C

43

N/C

19

N/C

44

N/C

20

N/C

45

N/C

21

N/C

46

N/C

22

N/C

47

N/C

23

N/C

48

N/C

24

N/C

49

N/C

25

N/C

50

N/C

ALARM CABLE CONNECTIONS

WIRE COLOUR

ALARM SIGNAL

BROWN

FAN ALM NC

WHITE

FAN ALM COM

BLUE

FAN ALM NO

BLACK

MAJOR ALM NC

ORANGE

MAJOR ALM COM

RED

MAJOR ALM NO

VIOLET

MINOR ALM NC

GREEN

MINOR ALM COM

YELLOW

MINOR ALM NO

CAN BUS

PIN #

SIGNAL

1

GND

2

CAN H

3

N/C

4

CAN L

5

N/C

6

N/C

A

B

C

D

E

1

2

3

4

5

D

A

C

E

B

1

3

5

4

2

DO NOT SCALE DRAWING

Summary of Contents for ALPHA OUTBACK ENERGY Cordex HP LPS36 Compact

Page 1: ...Your Power Solutions Partner Cordex HP LPS36 Compact Installation Manual Part 0300189 J1 Effective 07 2020...

Page 2: ......

Page 3: ...olo gies No part of this documentation shall be reproduced stored in a retrieval system translated transcribed or transmit ted in any form or by any means manual electric electronic electromechanical...

Page 4: ...0300189 J1 Rev B 2...

Page 5: ...Installation 10 5 1 General Instructions 10 5 2 Safety Precautions 10 5 3 Tools Required 11 5 4 Input and Output Wiring 20 6 Warranty and Service Information 25 6 1 Technical Support 25 6 2 Warranty...

Page 6: ...ath which the information appears CAUTION CAUTION indicates safety information intended to PREVENT DAMAGE to material or equipment Cautions are designated with a yellow warning triangle the word CAUTI...

Page 7: ...t with internal components Hazardous electrically live parts inside this unit are energized from the batteries even when the AC input power is disconnected The enclosure which contains the DC or AC po...

Page 8: ...features include major and minor alarms for monitoring connectorized cable output and one side mounting This product is particularly suitable for remote OSP power cabinets where free rack space is ti...

Page 9: ...0 pin amp champ style connector Alarm TE Style Connections to be cut if not needed Mechanical 6 shelf 4 modules P N 0300189 001 Dimensions HxWxD 88 mm x 149 mm x 305 mm 3 6 in x 5 9 in x 12 in Weight...

Page 10: ...ED per converter refer to the 0120011 J1 manual for details Fan tray Fan Tray Failure Alarm red MTBF 400 000 30 C 86 F ambient test model Telcordia SR 332 Issue 2 2006 Agency Compliance Safety CSA UL...

Page 11: ...listed and rated for 300 400 Volts voltage breakdown range 4 1 4 Transient Response The LPS36 output has been designed to provide protection against typical input and output voltage surges For exampl...

Page 12: ...erter system though not dangerous in voltage has a high short circuit current capacity that may cause severe burns and electrical arcing The DC output is a potentially dangerous voltage Do not touch t...

Page 13: ...LPS36 Compact must be grounded via a copper ground conductor Before making connections all bare grounding connection points to the LPS36 Compact must be cleaned and coated with an anti oxidant soluti...

Page 14: ...an outside plant enclosure The bracket can be assembled to the left or right side of the shelf depending on the installation When a fan tray is used the shelf can be in any orientation de pending on...

Page 15: ...13 RIGHT SIDE MOUNT WITH FAN TRAY LEFT SIDE MOUNT WITH FAN TRAY Figure 4 Rack Mount shelf only Left side with Fan Tray Figure 5 Right Side Mount with Fan Tray...

Page 16: ...0300189 J1 Rev B 14 NOTE THE LPS36 MODULES ARE INSTALLED UP SIDE DOWN AIR FLOW AIR FLOW Figure 6 Rack Mount Left Side Figure 7 Rack Mount Left Side LPS modules upside down...

Page 17: ...15 AIR FLOW AIR FLOW...

Page 18: ...n both sides 3 Cut the cable tie holding the fan connector to free the fan wire 4 Remove the wire grommet from the fan tray and wrap it on fan wire about 1 1 2 from the connector 5 Slide the back side...

Page 19: ...17 WRAP FAN CABLE WITH GROMMET MATE CONNECTORS AFTER TRAY IS SECURED...

Page 20: ...r cooling without a fan tray 3 Forced air cooling with a fan tray 1 3 4 44mm MIN 1 3 4 44mm MIN OPEN SPACE OR ANY EQUIPMENT THAT DOES NOT EXPEL OR RADIATE HEAT VERTICALLY OPEN SPACE OR ANY EQUIPMENT T...

Page 21: ...CLOSED HARD SURFACE 7 8 22mm MIN 7 8 22mm MIN THERMAL MANAGMENT WITH FAN TRAY A MINIMUM OF 1 2 RU 7 8 AIR GAP ON BOTH AIR INTAKE AND EXHAUST SIDES OF THE SHELF ARE REQUIRED FOR PROPER COOLING THIS APP...

Page 22: ...e the lugs with 1 4 20 serrated flanged nuts supplied to provide the anti rotation necessary for primary ground connections 4 The screws for securing the ground terminal plate can also be reoriented o...

Page 23: ...t The Anderson connector can be used or mated with Alpha part number 8700870 001 which provides two 8AWG wires with 2 hole lugs Check label on wire for connecting to proper polarity Figure 12 DC input...

Page 24: ...ay 29 15 May 29 15 K LAU THIRD ANGLE PROJECTION UNLESS OTHERWISE SPECIFIED DIM ARE IN MM INTERPRET DIM AND TOL PER ASME Y14 5M 1994 X X X X XX ANGULAR 1 1 0 5 0 25 ITEM GROUND TERMINAL 1 4 STUD 5 8 CE...

Page 25: ...190V_OUT3_MDL3 12 190V_OUT4_MDL3 37 190V_OUT4_MDL3 13 190V_OUT1_MDL4 38 190V_OUT1_MDL4 14 190V_OUT2_MDL4 39 190V_OUT2_MDL4 15 190V_OUT3_MDL4 40 190V_OUT3_MDL4 16 190V_OUT4_MDL4 41 190V_OUT4_MDL4 17 E...

Page 26: ...ET UL PGDQ2 REQUIREMENTS MATERIAL 3M 7883 OR 3M 7983 OR ALPHA APPROVED EQUIVALENT TEXT FONT IS ARIAL OR HELVETICA DIMENSIONS ARE IN mm KISS CUT LINES MODULE 2 1 MODULE 4 3 MODULE MODULE 1 2 3 4 15 0 3...

Page 27: ...l damages based upon equipment failure during or after the warranty period No other obligations are expressed or implied Warranty also does not cover damage or equipment failure due to cause s externa...

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...dquarter Germany Hansastrasse 8 D 91126 Schwabach Tel 49 9122 79889 0 Fax 49 9122 79889 21 Mail info alpha outback energy com France and Benelux fbnl alpha outback energy com Spain spain alpha outback...

Reviews: