background image

15

Main Screen by Mode & Product Information

The current mode is displayed among DMX mode, user mode and color mode(not applicable model) in the upper left corner of 
the main screen, and the DMX address number of the equipment is displayed in the middle with a yellow number. 
At the bottom, the current lighting value and fixture temperature are displayed, and some lighting value can be adjusted on the 
main screen by touching the value.

User can check information such as manufacturer, product model name, firmware version, UID 
number, current temperature of equipment, usage time of equipment, LED usage time, website, 
manual download link, etc. by clicking the INFO button on the main screen.
Through each ‘Menu – INFO’ touch, user can check the menu description and functions

Description and 

function of each menu

(DMX MODE)

(USER MODE)

(COLOR MODE)

Summary of Contents for FS Series

Page 1: ...LED LIGHTING FOR UHD BROADCASTING EST 2008 USER MANUAL SPOT LIGHT FS SERIES ...

Page 2: ...y chain on the product when installing and moving 4 Please install the signs below for people to bypass when install the product on high truss 5 The work should be done under the direction of approved specialist who is trained in safety and mechanical installations 6 The brightness and color temperature before and after aging may be different Safety Information WARNING ...

Page 3: ...en Instruction 13 Menu Tree 14 Main Screen by Mode Product Information 15 DMX Mode Channel Change Address Setup 16 User Mode Intensity ColorTemperature TintAdjust 17 Color Mode Not applicable model Extra Function Sleep Mode Function 18 Master Function 18 RDM Function 18 Dimming Speed Setup 18 Fixture ID Number Setup 19 Fixture Label Setup 19 Error Information Temperature Sensor 20 Network Connecti...

Page 4: ...rce projected by the lens is very soft Also the boundary of the shadow is formed smoothly without sharpness Beam cutting is excellent by adjusting the angle of the barn door FS Series is light weight compare to capacity and designed sturdy housing FS Series applies wireless DMX communication method so user can set up lighting fixture simply without a signal cable The Smart Touch LCD control that i...

Page 5: ...4 Fixture Exterior View Yoke Focus Knob Install Area Smart Touch LCD Screen Handle Install Area Connector Panel Fixed Knob Install Area ...

Page 6: ...5 Dimensions FS1000 FS1500 mm inch ...

Page 7: ...6 Dimensions FS2000 mm inch ...

Page 8: ...7 Dimensions FS3000 FS5000 mm inch ...

Page 9: ...nsumption 180W 250W 350W 500W 650W LED Chip 300W CSP LED 300W CSP LED 400W CSP LED 600W CSP LED 800W CSP LED White Light CCT Full 2 900 6 000K VCT CRI 95 98 Dimming 0 100 16 bit Control 5 PIN DMX In and Out Smart Touch LCD Controller RDM Option Wireless DMX512 Wireless RDM Remote Device Management RDM Setup Ambient Temperature Operation 20 45 C IP Rating IP20 Estimated LED Lifetime Over 50 000 hou...

Page 10: ...m Source Four 15 55 Zoom set at 50 cosine ISO Luminace Diagram 10 50 FS1000 50 FS1500 50 FS2000 50 FS3000 50 FS5000 50 844 1395 1983 2947 4130 331 552 773 1163 1620 178 297 408 615 850 110 185 250 391 535 Illuminance lux 9 ...

Page 11: ... 5 USBPORT forADMINISTRATORONLY Do not connect USB without administrator s permission 1 Observe the proper voltage range 2 If power is supplied outside the range noise may be generated from the SMPS 3 If the operating voltage is out of the proper voltage range SMPS function may be degraded or damaged ...

Page 12: ...er lighting fixture If user uses a standard DMX controller the DMX output of the controller can connect directly to the DMX input of the first fixture in the DMX chain User must use an adapter cable for connect the DMX controller to other XLR output Connect the DMX output of the first lighitng fixture in DMX chain to the DMX input of the next fixture and connect one output to the input of the next...

Page 13: ... Locked Fixture ID Screen Locked When the fixture is turned on the Smart Touch screen automatically locked To unlock the touch screen touch the finger icon three times If you do not touch for 30 seconds the lock is reset A A A ...

Page 14: ... 8 Home Return to the main screen 9 DMX512 Mode Address Setup Set channel mode and DMX512 address 10 User Mode Setup Set Intensity CCT and Tint manually 11 ColorModeSetup Notapplicablemodel Set RGB lighting color Saturation and Intensity 12 Setting Setting or changing the function of the equipment 13 Fixture ID Displays numbers for equipment management 14 Equipment Information Displays the help th...

Page 15: ...ription of fixture ID Θ Information Basic equipment information Θ Rotate Θ Home Main screen Θ DMX512 Mode DMX mode select DMX address input Θ Information DMX channel value Θ User Mode Intensity setup Color temperature setup Θ Information Description of each function Θ Color Mode Not applicable model RGB color setup Saturation setup White setup Θ Full screen Individual RGB setup and Preset Θ Inform...

Page 16: ...and fixture temperature are displayed and some lighting value can be adjusted on the main screen by touching the value User can check information such as manufacturer product model name firmware version UID number current temperature of equipment usage time of equipment LED usage time website manual download link etc by clicking the INFO button on the main screen Through each Menu INFO touch user ...

Page 17: ...ue To return to the previous screen press the Info button again Support channels and features vary by product User can move to the DMX channel change screen by selecting DMX512 MODE button in main screen In DMX512 MODE screen user can select DMX channel mode on top tap and input DMX512 address by pressing the number pad DMX MODE It is used to adjust by DMX512 signal ...

Page 18: ...ue by dragging Drag the activated bar close to the desired value and then touch to set the exact value USER MODE It is used when the user directly manipulates the equipment Intensity The number indicates the current brightness value of the fixture and is displayed from 0 to 100 CCT The number indicates the current color temperature value of the fixture and is displayed from 2 900 to 6 000K Pressin...

Page 19: ...tures without a console connection If Off the DMX signal will follow RDM setup Default On Set the feature that enables bi directional wireless communication through RDM equipment If Off this equipment will not be searched on RDM equipment Dimming speed setup The number indicates the current dimming speed value of the fixture and is displayed from 0 to 40 The higher the value the slower the dimming...

Page 20: ...vice is basically the model name and it can be changed through RDM communication but it can t be changed through the Smart Touch LCD When changing the label of the device through RDM enter the device name English and the management number in the Device Label field The entered contents are displayed in the upper left corner The fixture ID is automatically displayed in 3 or 4 digits from automatical...

Page 21: ...LED output will be 0 and Temperature Error Please Check Device will be displayed The error messages are only displayed on the main screen and the fixture ID screen Even if the temperature falls to the normal range It does not disappear In this case normalize the temperature of the equipment and restart it Temperature Sensor When the DMX512 network connection is lost the DMX512 address number in ma...

Page 22: ...21 DMX Protocols 1 2 Channel Mode Mode Channel DMX Value Function 1 1 0 255 0 100 Dimmer 2 1 0 255 0 100 Dimmer 2 0 255 0 100 Color Temperature CCT ...

Page 23: ... 5150K 184 187 5200K 188 191 5250K 192 195 5300K 196 199 5350K 200 203 5400K 204 207 5450K 208 211 5500K 212 215 5550K 216 219 5600K 220 223 5650K 224 227 5700K 228 231 5750K 232 235 5800K 236 239 5850K 240 243 5900K 244 247 5950K 248 255 6000K DMX Value Function 88 91 4000K 92 95 4050K 96 99 4100K 100 103 4150K 104 107 4200K 108 111 4250K 112 115 4300K 116 119 4350K 120 123 4400K 124 127 4450K 12...

Page 24: ...L YES YES SENSOR_DEFINITION YES SENSOR_VALUE YES DMX_PERSONALITY YES YES DMX_PERSONALITY_DESCRIPTION YES STATUS_MESSAGES YES Lamp Controls No Control Property Value Example Description UserSettings Remarks 1 Identify On N A Device identification action active Enable Identify device Same as On 2 Identify Off N A Device identification action inactive Enable Identify device Same as Off 3 Cold Reset N...

Page 25: ...Start Address 1 DMX address Enable 1 512 Range 7 Device Hours N A N A Display only no actual response 8 Lamp Hours N A N A Display only no actual response 9 Lamp State N A N A Display only no actual response 10 Lamp On Mode N A N A Display only no actual response 11 Display Invert On LCD screen display direction Enable Off 0 On 180 Auto Current opposite direction 12 Identify Device Off Selected fi...

Page 26: ...00K Color Temperature 1 Ch 3000K 1 Ch Mode 3000K Color Temperature 1 Ch 3100K 1 Ch Mode 3100K Color Temperature 1 Ch 3200K 1 Ch Mode 3200K Color Temperature 1 Ch 4400K 1 Ch Mode 4400K Color Temperature 1 Ch 4500K 1 Ch Mode 4500K Color Temperature 1 Ch 5500K 1 Ch Mode 5500K Color Temperature 1 Ch 5600K 1 Ch Mode 5600K Color Temperature 1 Ch 5700K 1 Ch Mode 5700K Color Temperature 1 Ch 6000K 1 Ch Mo...

Page 27: ......

Reviews: