9
Subject to change without notice | 83030600dUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Unscrew the front facing panel of the ventilation
and domestic hot water module…
Drain the domestic hot water tank through the valve
mounted on site at the cold water connection…
After completely draining the tank, remove the
foam cover above the service opening of the
domestic hot water tank, unscrew the flange cover
of the service opening and clean the domestic hot
water tank…
1 Electrical switch cabinet, ventilation
and domestic hot water module
2 Service opening, domestic hot water
tank (shown here under foam cover)
3 External current anode (under foam cover)
Then tightly close the flange cover again, insert the
foam cover and replace the front panel back on the
ventilation and domestic hot water module…
Fold down the swivelling door of the ventilation
and domestic hot water module, tighten the quick-
release screws and switch unit back on again...
Refill the domestic hot water tank of the ventilation
and domestic hot water module.
Check the safety valve (provided by customer) for the
hot water tank at regular intervals. Since an external
current anode is built in, the anode requires no
maintenance.
It is a good idea to have a maintenance contract with a
heating installation company. The company will conduct
all required maintenance at regular intervals.
Summer function
NOTICE.
The summer function can only be used in con-
junction with a geothermal heat exchanger (pro-
vided by the customer).
To prevent the supply air from being blown into the
rooms preheated during the hot season, you must
uncouple the heat exchanger from the air flow.
Switch off the unit and then open the upward
swivelling / hinged door of the ventilation and
domestic hot water module and remove the two
filters from the unit…
Maintenance of the unit, filter, , page 6
Pull out the two filters on the top right and left-
hand side of the heat exchanger and pull out the
moulded part above the heat exchanger from the
front of the unit…
Maintenance of the unit, counter flow heat
exchanger, – , page 7
Remove the small triangular piece from the moulded
part…
1 “Large” triangular piece
2 “Small” triangular piece
NOTICE.
Store the “small” triangular piece in a safe dry
place until the end of use of the summer func-
tion.
Push the “large” triangular piece only back into the
unit…