17
Subject to change without notice | 83030600dUK – Translation into English of the original German operating manual | ait-deutschland GmbH
To do this, push the flexible pipe over the connecting
socket and fix with hose clips…
Insulate flexible pipe.
EXTRACT AIR INTEGRATION (KHZ-LW… ONLY)
First, insert the connecting sleeves supplied with
the KHZ-LW … in the opening provided in the
intake cover also included with the KHZ-LW …
1 Intake cover with opening
2 Connecting sleeves
Attach this intake cover on the short, straight duct
of the air duct system (accessory which must be
purchased), which then becomes the intake duct…
“Assembly and installation of the air ducts”
section in the operating manual of the air/water
heat pump.
Install the intake duct on the rear of the air/water
heat pump with the help of the unit connection
set…
Connect the connection for extracted air at the
ventilation and domestic hot water module with the
connecting sleeve at the intake duct via the flexible
pipe supplied with the KHZ-LW …