5. Use cable ties (
separate pack) to fix the LIN bus
cable to a web of the masking plate around 20 cm
in front of the connector (strain relief).
200 mm
6. Push the cable through the opening in the front
panel of the unit from below and into the control.
7. Press the lugs of the control into the openings in
the front panel of the unit.
Mount the control on the wall and connect
IMPORTANT
Mount the wall bracket with control panel
only ver-
tically
on a wall!
1.
Release the rear bracket from the control.
2.
If visually unattractive: Cut off the lugs on the rear
of the control (are only needed to insert in the
front panel).
3.
Mark 2 drillholes (
Dimensional drawing “Wall-
mounted bracket”, page 32).
4.
If cables are fed in from underneath: Break out
the web at the bottom in the middle of the wall
bracket. Use side-cutters if necessary.
5.
Fix the wall-mounted bracket
(②)
with 2 wall
plugs
(①)
and 2 screws
(③)
.
6. Feed in the cables from the wall (e.g. in-wall box)
or from below.
7. Route the LIN bus cable from the top right-hand
side at the rear from the heat pump and plug into
the control at the bottom.
8.
Push the control onto the wall-mounted bracket.
9.
Put on the masking plate if applicable
(accessories).
7
Flushing, filling and venting
7.1 Remove the front panel of
the module box
►
Unscrew the front panel of the module box.
7.2
Fill, flush and vent heat source
Frost protection must be provided in the heat source.
Below are the approved antifreeze agents based on:
●
Monopropylene glycol
●
Monoethylene glycol
●
Ethanol
●
Methanol
Antifreeze agents based on salt are not permitted.