Connect the compressor load cable to the wall-moun-
ted controller using the plug included with the heat
pump:
N = blau / blue
= gelb-grün / yellow-green
L1 = braun / brown
L2 = schwarz / black
L3 = grau / grey
N = blue
= yellow-green
L1 = brown
L2 = black
L3 = grey
ATTENTION
Ensure clockwise rotary field of the load power
supply (compressor).
Operation with the incorrect rotary direction
of the compressor can cause serious, irreparable
damage to the compressor.
ATTENTION
The power supply for the heat pump must be
equipped with an all-pole miniature circuit-breaker
with at least 3 mm contact spacing to IEC 60947-2.
Residual current circuit breaker type B If required.
Note the tripping current.
“Technical data / scope of supply” overview, “Elec-
trics” section.
NOTE.
In devices with integrated electric heating element,
the electric heating element is connected for 9 kW
(6 kW) in the factory. At contactor Q, it is possible
to select 6 kW (4 kW) = 2 phase operation.
Disconnect Q5/6 for this. Or 3 kW (2 kW) = 1
phase operation. Disconnect Q5/6 and Q5/4 for this.
The values in brackets are for the 6 kW heating
element. Disconnected cables must be furnished
with screw terminals. Only the phases cited above
may be disconnected (safety temperature limiter).
POWER CONNECTION
If the unit is closed, take off the facing panel…
The power cables are pulled through the opening in
the baseplate and are routed through the cable duct
and into the switch area…
1 Cable duct
2 Opening in the baseplate
Connect the power cable to the following terminals:
1 230V
2 Heating element
3 Compressor
NOTE.
Example for power connection: Connections must
be done as described in terminal diagram.
Lay the power cable in a cable conduit up to the cable
entry into the building and from there continue laying
it up to the fuse box…
Connect the power cable to the power supply.