9
Subject to change without notice | 83054200iUK | ait-deutschland GmbH
16
Installation and assembly
Observe the following when performing all work:
NOTE
Always comply with applicable accident pre
-
vention regulations, statutory regulations, or
-
dinances and directives.
NOTE
Observe the sound levels of the respective
model.
“Technical data / scope of delivery“, from
page 22, “Sound” section.
16.1 Installation site requirements
9
Perform installation outdoors only.
9
Clearance dimensions are met
“Dimensional drawings“, from page 27, and “In
-
stallation plans“, from page 29, for respective
unit model
NOTE
The noise emissions of the heat pumps
must be taken into account in the respective
installation plans for air/water heat pumps.
The respective regional regulations must be
observed.
9
Free air intake and blowing air are possible with
-
out any air short-circuit.
9
The surface is suitable for installation of the unit:
● The foundation is level and horizontal
● The surface and the foundation have a load-
bearing capacity sufficient for the unit’s weight
9
Ground surface in the air outlet area of the heat
pump is permeable to water
16.2 Transport to installation site
To prevent damage during transport, always transport
the unit to final installation site in its original packaging,
using a lifting truck, forklift or crane.
WARNING
Several people are required to transport
the unit. Do not underestimate the weight
of the unit.
“Technical data / scope of delivery“, from
page 22, “General unit data” section.
WARNING
Unit is not fastened to the wooden pallet.
Danger of tipping over during transport!
This can result in personal injury and dam-
age to the unit.
► Take suitable precautionary measures to
eliminate the danger of tipping.
IMPORTANT
Never use components and hydraulic con
-
nections on the unit for purposes of transport.
IMPORTANT
Do not tilt the unit more than a maximum
of 45° (in any direction).
Lifting the unit with pipes
only LW 140… and LW 180…
The units LW 140… and LW 180… can be lifted with
¾” pipes (provided by customer) that are suitable for
the weight of the respective unit. Special holes are
provided in the frame for this purpose.
NOTE
The unit type LW 251A cannot be lifted with
pipes.
1. Remove the lower facing panels of the unit.
“16.4 Attaching the air flow baffles”, page 11,
point 1.
2. Insert the pipes through the holes in the frame on
the switch box side.