background image

31

We reserve the right to modify technical specifications without prior notice.
83053600bUK – Translation of the operating manual 

© Alpha-InnoTec GmbH

ec declaration of conformity

The undersigned
"confirms that the following designated device(s) as designed and marketed by us fulfill the standardized Ec directives, 
the Ec safety standards and the product-specific Ec standards. In the event of modification of the device(s) without 
our approval, this declaration shall become invalid."

designation oF the deviCe(s)

Heat pump

unit model

number

unit model

number

LWD 50A

100 601

+  HMD 1

150 705

LWD 70A

100 602

+  HMD 1

150 705

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

eC direCtives

standardized en

2006/42/EG

EN 378

EN 349

2006/95/EG

EN 60529

EN 60335-1/-2-40

2004/108/EG

EN ISO 12100-1/2

EN 55014-1/-2

97/23/EG

EN ISO 13857

EN 61000-3-2/-3-3

* pressure equipment Component

Category

II

Module

A1

Designated position:

"TÜV-SÜD

 

Industrie Service GmbH (Nr.:0036)"

Company:

Place, date:

Kasendorf, 20.07.2011

Signature:

"Jesper Stannow 

Technical Director"

Summary of Contents for HMD 1

Page 1: ...ify technical specifications without prior notice 83053600bUK Translation of the operating manual Alpha InnoTec GmbH Accessories for Dual Air Water Heat Pumps Operating Manual HYdraulic Module HMD 1 H...

Page 2: ...comply with the parameters for the respective model This operating manual is intended only for persons assigned to work on or operate the unit Treat all constituent parts confidentially The informatio...

Page 3: ...t 11 Safety assembly 11 Expansion vessels 11 Electrical connections 12 Connect BUS cable 13 Flushing filling and bleeding the system 14 Flushing filling and bleeding the heating circuit 14 Insulating...

Page 4: ...escribed in this operating manual and this work has not been explicitly approved by the manufacturer in writing if the unit or components in the unit have been altered modified or removed without the...

Page 5: ...r heat pump or heat pump system operates efficiently and ecologically the following are especially important Energy saving tip Avoid unnecessarily high flow temperatures A lower flow temperature on th...

Page 6: ...error compressor intake Check sensor replace if necessary 764 Sensor error Compressor heater Check sensor replace if necessary 765 Overheating longer than 5 minutes below 2K When switching on for the...

Page 7: ...cians zus tzlich bei reversibler Variante 1 bergangsst ck 2 Gewindeabdeckungen 3 3 Isolation f r bergangsst ck Check the delivery for outwardly visible signs of damage Check that nothing is missing fr...

Page 8: ...1 E HMD 1 R E Components of the unit 1 Safety assembly for heating circuit insulated 2 Air separator 3 Continuous flow heater 6kW 4 Flow monitor 5 Expansion vessel 12l 6 Circulating pump for heating...

Page 9: ...the unit to final installation location in its original packaging Attention The unit must not be lifted up by the switch box and transported www alpha innotec de D 95359 Kasendorf Industriestra e 3 Al...

Page 10: ...Natural stone with sealed joints Solid sand lime blocks Perforated sand lime bricks Solid bricks Vertically perforated bricks Hollow floors ceilings made of clay bricks concrete or similar Solid gypsu...

Page 11: ...ing the unit to the heating circuit see Flushing filling and bleeding the system Note Contamination and deposits in the heating cir cuit can cause malfunctions Install filling and draining devices shu...

Page 12: ...latter Warning Install electric connections only according to the terminal diagram that applies to your model Note All live wires must be stripped before they are installed in the cable duct of the sw...

Page 13: ...shield into the shield terminal Feed the end with the individual cores through one of the two grommets Core assignment 1 12 V 2 GND 3 LIN Use cable ties and heat transfer compound to fix the return f...

Page 14: ...re commissioning Contamination and deposits in the system can cause malfunctions Flushing filling and bleeding the heating circuit Attention Do not exceed a pressure of 2 5 bar when flushing the unit...

Page 15: ...ap of the safety assembly are open If the heating circuit is filled or emptied the bleeding valve opens Open shut off valves in the hydraulic module on the heat pump side Close shut off valves of the...

Page 16: ...One precondition is that a shielded network cable category 6 has been installed through the unit as part of the electrical connec tion work Operating manual for the heating and heat pump regulator ve...

Page 17: ...rovide for proper disposal of unit components in accordance with the applicable regulations standards and directives Removal of the buffer battery Attention Before scrapping the heating and heat pump...

Page 18: ...ermissible operating pressure bar Integrated expansion vessel Volume Initial pressure yes no l bar Buffer tank integrated yes no Heat metering and or flow rate display integrated yes no General unit d...

Page 19: ...1 5 12 1 5 695 550 330 695 550 330 695 550 330 695 550 330 25 25 25 25 R 1 Innen R 1 Innen R 1 Innen R 1 Innen R 1 Innen R 1 Innen R 1 Innen R 1 Innen 3 N PE 400V 50Hz C16 3 N PE 400V 50Hz C16 3 N PE...

Page 20: ...Pressung HMD 1 812027 Seite 1 1 Zeichnungsnummer Freie Pressung HMD 1 812027 PEP 006 2011 Liska 12 07 2011 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 0 0 5 1 0 1 5 2 0 2 5 3 0 p bar p PI p PII p PIII m3 h...

Page 21: ...cal specifications without prior notice All dimensions in mm A Front view D Side view from right The hydraulic module is installed in the heating flow Item Designation Dim 1 Control element 2 Return f...

Page 22: ...forward flow Rp 1 IG 5 Penetrations for electric sensor cables We reserve the right to modify technical specifications without prior notice 83053600bUK Translation of the operating manual Alpha InnoTe...

Page 23: ...odul 0001 819403 a PEP 006 2011 PEP 001 2012 30 6 2011 8 5 2012 RA RA Blatt von Werkstoff Gewicht Ma stab 1 10 Det Ma stab Datum Name Erstellt Gepr Norm 30 6 2011 Aepfelbach toleranz Allgemein DIN ISO...

Page 24: ...nderungen vorbehalten Alle Ma e in mm OKF Oberkante Fertigfussboden FS Freiraum f r Servicezwecke PS Freiraum f r wandh ngenden Pufferspeicher 50L Zubeh r m glich 5 4 3 2 1 A B C D E F 4 3 2 1 Zust nd...

Page 25: ...or notice 83053600bUK Translation of the operating manual Alpha InnoTec GmbH Installation plan HMD 1 R E 1350 600 200 380 FS OKF 500 850 FS Legende 819413 Technische nderungen vorbehalten Alle Ma e in...

Page 26: ...A3 PE TA M X A4 L1 L1 N Charge discharge cooling mixer 1 open MOT X10 EVU L2 TBW BUP GND Hot water or buffer storage tank ZW2 SST GND 5 RFV 3 N PE 400V 50Hz TA 5 3 A5 TBW X9 HUP N GND X8 PE X3 L3 M 3...

Page 27: ...PE 400V 50Hz LIN bus Power supply compressor output external unit 3 N PE 400V 50Hz LIN Power supply compressor right hand rot field is mandatory Hydraulic module HMD 400V 817378 Achim Pfleger 19 05 20...

Page 28: ...emperature limiter additional heating M4 Legend Flow sensor TVL 1 N PE 230V 50Hz K12 230VAC bl C 1 M5 Heating pump not installed if Energy Efficiency option installed br Operating materials EVU 1 Cont...

Page 29: ...E 400V 50Hz LIN bus Power supply compressor output external unit 3 N PE 400V 50Hz LIN Power supply compressor right hand rot field is mandatory Hydraulic module HMD 400V 817378 Achim Pfleger 19 05 201...

Page 30: ...mperature limiter additional heating M4 Legend Flow sensor TVL 1 N PE 230V 50Hz K12 230VAC bl C 1 M5 Heating pump not installed if Energy Efficiency option installed br Operating materials EVU 1 Contr...

Page 31: ...modification of the device s without our approval this declaration shall become invalid Designation of the device s Heat Pump Unit model Number Unit model Number LWD 50A 100 601 HMD 1 150 705 LWD 70A...

Page 32: ......

Reviews: