To wash, proceed as follows:
a) immerse the electrostatic cell in the tray with the detergent and leave to soak for 5÷10minutes
b) remove the electrostatic cell and rinse thoroughly with running water, taking care not to break the
ionisation wires
c) remove the cell and leave it to dry in a warm place, keeping it raised from the ground by wooden strips
(ovens with a maximum temperature of 60°C are tolerated).
d) examine the state of the ionisation wires, stretching them slightly to check their mechanical strength.
Use a cotton flock and methylated spirits to remove any residual traces of dirt.
e) Ensure that the cell is thoroughly clean and dry before reinstalling it.
When maintaining the pre-filter, first remove the dust deposited in it using an ordinary vacuum cleaner. Then
proceed with washing as follows:
a) immerse the pre-filter in the tray containing the detergent diluted in warm water and leave to soak for
about half an hour.
b) remove the pre-filter from the tray and rinse thoroughly with water.
c) leave to dry in a warm ventilated environment.
6.2 General inspection of the filters
The state of the filters must be inspected every time they are washed so as to prevent air cleaner malfunction
and problems.
16
6 . 1 . 2
W a s h i n g t h e f i l t e r s
Filter maintenance is important both for the correct operation of the machine and for constant performance
with the passage of time. The following materials are required for maintenance:
1) Two plastic trays, one with the bottom raised 2-3 cm for decanting the dirt. As an alternative to the raised
bottom, use a stainless steel frame.
2) Non-corrosive detergent for washing the electrostatic cells, supplied by an authorised dealer.
3) A rubber tube for rinsing the filters.
4) Vinegar.
Prepare the tray with the raised bottom with warm water (max 45°C). Dilute the detergent in the proportions
indicated on the label of the detergent itself.
Put the vinegar and water in the other (1 litre of vinegar for every 20 litres of water).
water and detergent
tray in plastic or stainless steel
electrostatic cell
frame in plastic or stainless steel
To wash, proceed as follows:
a) immerse the electrostatic cell in the tray with the detergent and leave to soak for 5÷10minutes
b) remove the electrostatic cell and rinse thoroughly with running water, taking care not to break the
ionisation wires
rinsing with current water
drying
rising with current water
drying
Inspection
Fault
Operation
ionisation wires
breakage of a wire
change the ionisation wire 105
ionisation wires
rough surface with material deposits
clean the wire with a cloth soaked in
alcohol or replace
ceramic insulators
dirty with material deposits
wash the cell again
ceramic insulators
breakage or presence of cracks
replace the insulators
high voltage terminal strip
burning caused by high voltage
replace the high voltage terminal strip