background image

3

ALMECO nv 

Air and water technologies

Royennestraat 51, B-7700 Moeskroen

[email protected] - www.almeco.eu

JETBLACK SAFET Y PERSONNEL CLEANING STATION

Please read the following installation, operation and maintenance instructions carefully. Always ensure that the power 

is isolated before commencing any maintenance on the Cleaning Station. This manual is also available from the marked 

download section of our website: www.almeco.eu 

WARNING: 

DO NOT USE with hazardous materials, the Cleaning Station airstream could move the hazardous materials to 

other areas. If removing a hazardous material a JetBlack Safety Cleaning Booth will be required for containment. DO NOT 

misuse this product or use on broken skin, even very low-pressure air can pose a risk! 
This product is intended to be used for personnel clean down, or for general particle removal. Ensure that all necessary PPE is 

worn.

1. GENERAL SAFETY & OPERATION

•  Attach the ‘OSHA’ guard provided to the main nozzle assembly before operating. This can be easily done by simply sliding

the guard onto the end of the nozzle

•  Never use in a wet environment 
•  Never allow objects to pass through the guard whilst the fan is rotating
•  Always switch off the unit at the main electrical supply and disconnect the plug before performing any cleaning or 

maintenance operations on the Cleaning Station

•  Never use a pressure washer or steam washer to clean the Cleaning Station 
•  Eye, ear and respiration protection must always be worn whilst operating
•  The Cleaning Station has a thermal shutoff device for safety purposes. Prolonged use may cause the unit to shut-off. In 

this case, switch the unit off and wait for a few minutes before re-using

•  Please note - the air from the Cleaning Station will become warm with prolonged use
•  These units are not designed for continuous use
•  The Cleaning Station is suitable for safe area installation only and 

must not be used in ATEX zones or near the presence of 

explosive substances

2. CLEANING STATION SAFETY INFORMATION

WALL MOUNTED UNITS 

Electrical Safety

• 

This equipment is designed to be hard wired to a fused supply. Check that the correct wire gauge is used and that the 

correct voltage is available before connection. Refer to the Cleaning Station rating plate for full details – this is located on 

the side of the Touch Switch Box 

• 

The Cleaning Station can be fitted with a speed controller, which allows for the speed to be changed 

• 

Any attempt to change the timer switch settings will invalidate the warranty 

• 

The Cleaning Station should be connected to an electrical supply that is surge protected and in compliance with local 

codes

• 

The appliance must be earthed

• 

Always shut off the supply power and isolate the Cleaning Station before performing any maintenance operations 

General Safety

• 

The Cleaning Station is supplied with a touch activated time switch, mounted in a weatherproof enclosure sealed to an 

IP55 rating

• 

To operate, press the ‘Touch’ button. The Cleaning Station will run for 30 seconds – if you require less time, simply press 

the ‘Touch’ button again, and the unit will turn off

• 

If an anti-static unit has been fitted, a second switch is located on the front of the Cleaning Station – the switch must be 

on ‘I’ for the anti-static pack to work correctly

Summary of Contents for Jetblack Safety

Page 1: ...www almeco eu DRYING BLOW OFF SOLUTIONS JETBLACK SAFETY PERSONNEL CLEANING STATION Wall mounted portable versions Installation operation and maintenance instructions...

Page 2: ...meco eu Manual content 1 General safety information 3 2 Cleaning station safety information 3 3 Your new unit 4 4 Installation 5 5 Maintenance service 6 6 Spare parts 7 7 Trouble shooting 7 8 Waranty...

Page 3: ...shutoff device for safety purposes Prolonged use may cause the unit to shut off In this case switch the unit off and wait for a few minutes before re using Please note the air from the Cleaning Statio...

Page 4: ...lease immediately contact the Distributor that you purchased it from NOZZLE ASSEMBLY DETACHMENT Rotate the black coloured quick release fitting 90 degrees until it clicks Push the upper ring towards t...

Page 5: ...on using the four holes in the baseplate Ensure the four spacers supplied are fitted under the baseplate when fitting to the wall If the Cleaning Station is already fitted to the wall remove and fit s...

Page 6: ...mage below and pull the filter out of its locating hole then re insert a new filter and refit filter guard Portable unit filters First remove the 4 fixing screws filter guard as shown on the image bel...

Page 7: ...motor B3 003 325 110V replacement motor B3 003 057 230V replacement brushes B3 003 438 110V replacement brushes 7 TROUBLE SHOOTING Malfunction Possible Cause Remedy Low Airflow Dirty or contaminated b...

Page 8: ...f this document If the defect was due to accident or misuse operation in an application not approved by Almeco or unauthorised modification or repair Consumable parts and their routine replacement suc...