6. Installation and initial start-up
6.1. Installation location
Machine does not require special foundation and is not anchored to it. It is enough to ensure the flat floor of
sufficient load-bearing capacity and space.
There must be sufficient space for the operator and the maintenance and repair.
6.2. The Climatic operation conditions
Machine is designed for operation in premises with artificially controlled climatic conditions, for example in
closed heated and ventilated premises (no direct sunlight, rain, wind, sand and dust from the outside air, the
absence or substantial reduction of impacts of condensation of moisture) under the following conditions:
• ambient temperature: (+5-+40) °C;
• relative humidity: not more than 80% at 25 °C;
• dew is not allowed;
• the impact of corrosive gases is not permitted.
The temperature variation of the workspace is not specified.
Dust content of the work shop shall be within sanitary norms.
The place of installation of Machine should be selected in such a way as to exclude local heating or cooling
(Sun, heating, draughts, etc.).
Machine is not intended for use in explosive environments or near inflammable objects.
If you fail to comply with the requirements, there is the danger of fire and/or
explosion.
The manufacturer is not liable for defects or injuries caused as a result
of non-compliance with the requirements on service conditions.
6.3. Installation of the Melanger
Set the Melanger to work in accordance with points 6.1 and 6.2.
You should do the following:
1. Free the equipment from a transport package.
2. Perform a visual inspection of equipment for mechanical damage.
3. Check the tightness of the threaded connections.
4. Install the equipment on site to use it on a flat and solid horizontal area.
5. Make an electrical connection of the Melanger to the 230 V 50/60 Hz line with ground. The connecting
cord (cable) should be placed in such a way as to prevent its damage (kink, fracture, cut, etc.)
If necessary, open the body of the Melanger for the implementation of preventive and repair work is only
allowed to qualified personnel!
The electrical outlet must be grounded and be rated for a current of at least 6 A!