Ensure  that  you  have  inserted  a  valid  and  configured  SIM  card  and 
connected a GSM antenna. 

Integrate  the  come

2

ascos  device  into  your  system  as  shown  in  the 

preceding chapter. 

I

NITIALISATION

 

As soon as the come

2

ascos device is supplied with power, the initialisation 

starts.  This  process  lasts  for  about  10  to  20  seconds.  The  quality  of  the 
GSM signal is checked and if not sufficient, the modem restarts. 

R

EADY

 

A  slow  flashing  yellow  light  indicates  that  the  modem  has  registered  at 
GSM  net.  After  another  few  seconds  of  internal  initialisation  the 
come

2

ascos device is ready. In this state you can set the device into pause 

mode or start the process of connecting by sending a GGA message. 

C

ONNECTING AND 

A

UTHENTICATION

 

After receiving a GGA message the come

2

ascos device starts connecting to 

the  reference  service.  This  activity  is  indicated  by  the  green  LED.  The 
connecting procedure including the authentication lasts about one minute. 

D

ATA 

T

RANSMISSION

 

Both LEDs are constantly on. Correction data are being transmitted. If the 
connection  is  disconnected  because  of  low  GSM  signal  or  electromagnetic 
interferences  the  come

2

ascos  device  might  restart  automatically.  For 

improving  stability  please  read  the  chapter  about  “Performance 
Optimization”. 

In  order  to  reduce  GPRS  costs  you  can  stop  the  flow  of  correction  data 
temporarily by stopping the GGA output of your GNSS receiver or pushing 
the button at the front of the device for 2 seconds. The flow of correction 
data  is  activated  again  as  soon  as  a  new  GGA  message  is  received 
respectively  the  button  is  pushed  for  2  seconds.  In  GPRS  mode  the  data 
flow  is  resumed  quickly  within  only  a  few  seconds  as  the  come

2

ascos 

device stays online in pause mode. 
Push the button for 5 seconds for shutting down into stand by mode. 

Summary of Contents for COME2ASCOS

Page 1: ...QUICK REFERENCE COME2ASCOS UND COME2ASCOS BLUE ALLSAT GmbH Am Hohen Ufer 3A 30159 Hannover Germany Telefon 49 0 511 30 399 0 Telefax 49 0 511 30 399 66 Internet http www allsat de eMail info allsat de...

Page 2: ...QUICK REFERENCE COME2ASCOS AND COME2ASCOS BLUE 1 Last update 18 12 2008...

Page 3: ...iguration Software 7 Create configuration string manually 12 Configuration by SMS 15 Configuration by HyperTerminal 15 Configuration of the Bluetooth connection 16 Assembly come2ascos 18 Assembly come...

Page 4: ...on come2ascos is manufacturer independent and can be used as a correction data modem for different GNSS receivers You need a GSM card if necessary an additional GPRS tariff for operation As a supplier...

Page 5: ...the come2ascos device with stabilized power within a voltage range from 8 to 13 5 Voltage Start the configuration software and choose the serial interface at your Personal Computer Perform your indiv...

Page 6: ...SIM card again You will find the function for changing the PIN in the menu settings in many mobile phones Please note All saved SMS drafts on your SIM card will be deleted The come2ascos device saves...

Page 7: ...m via serial interface by SMS In the two last mentioned cases the configuration string has to be created manually You will find detailed information in the chapter Fehler Verweisquelle konnte nicht ge...

Page 8: ...our Personal Computer by the configuration cable Then proceed with the following steps Switch on the power supply The come2ascos device will register at the GSM net and indicate this state by a quickl...

Page 9: ...QUICK REFERENCE COME2ASCOS AND COME2ASCOS BLUE 8 figure 3...

Page 10: ...der is not listed it is explained below how you can add your individual entries to the pre defined settings CORRECTION DATA SETTINGS GPRS In this field the login details of your reference service prov...

Page 11: ...QUICK REFERENCE COME2ASCOS AND COME2ASCOS BLUE 10 figure 4...

Page 12: ...Configure Device The writing process needs several seconds while the come2ascos device should not be disconnected from power supply The button Read Settings from Device displays the current configurat...

Page 13: ...IFIER CONFIG MODEM BAUD_RATE MODUL MODULATION DIAL TEL_NUMMER OPTIONAL_PARAM Parameters semantics IDENTIFIER An identifier can be set as an optional parameter in order to distinguish between different...

Page 14: ...e Username and password are separated by colon MODULATION Unless a certain modulation type is not necessary for special applications use the standard setting autobauding For configuration use the keyw...

Page 15: ...d an automatic choice of a suitable reference station is needless then This parameter is reserved for GPRS connections NEED GGA is a keyword that must be set if the reference service uses the VRS conc...

Page 16: ...e configuration string is created like described in the chapter Create configuration string manually Additionally the string is exceeded by the Prefix PSLL and ends with a line feed CR NL Connect the...

Page 17: ...calls Thus every other active communication partner can built up a connection to the Bluetooth device For further setting options concerning the Bluetooth connection please take a look into the Free2m...

Page 18: ...QUICK REFERENCE COME2ASCOS AND COME2ASCOS BLUE 17 figure 6...

Page 19: ...ME2ASCOS BLUE 18 ASSEMBLY COME2ASCOS figure 7 Connect your come2ascos device as shown in figure 7 to power supply and your GNSS receiver by the split cable Don t forget connecting a GSM antenna GSM an...

Page 20: ...n module CHARGING Plug the connector of the battery charger into the charge socket beside the power switch Only use the battery charger delivered together with the come2ascos blue A full charge period...

Page 21: ...Ready off slowly flashing Send GGA message Connecting Pushbutton 2s Pause Mode Connecting quickly slowly flashing slowly flashing Please wait Authentication slowly flashing on Online authentication a...

Page 22: ...cos device starts connecting to the reference service This activity is indicated by the green LED The connecting procedure including the authentication lasts about one minute DATA TRANSMISSION Both LE...

Page 23: ...rs NTRIP LIST List of reference stations within the area of max 140 km GPRS STATUS GPRS gateway GPRS username GPRS password telephone provider received bytes transmitted bytes signal quality 3 is min...

Page 24: ...overage should be sufficient Best performance and stability is reached in areas with high signal quality If the coverage is not sufficient maybe another provider can offer a better net structure in yo...

Page 25: ...her Serial Port RS232 2400 57600 bauds 8 data bits 1 stop bit no parity POWER SUPPLY Voltage 7 5 15 5 VDC Supply current stand by 30mA 12VDC pause SMS 130mA 12VDC GPRS NTRIP 300mA 12VDC Peaks of curre...

Page 26: ...92 non condensing POWER SUPPLY Nominal voltage 6 VDC Accu capacity at least 2500mAh Operation time around 6 hours dependant on many different factors CONNECTOR The pin assignment of the 8 pin female...