BLUE

 

14 

071 

V.110/X.31 9600 

Transparent 

[TEL_NUMMER]: 

Telephone  number  to  the  modem  access  of  a 
reference service or an own reference station. 

[OPTIONAL_PARAM]: 

Further  parameters  can  be  optionally  set  by 
adding  them  to  the  configuration  string, 
separated by comma: 

 

MOUNT:[MOUNTPOINT]  allows  to  specify  a 
certain  mount  point  manually.  The  keyword 
MOUNT  is  followed  by  a  colon  and  the  name  of 
the source. This parameter is reserved for GPRS 
connections. 

 

SKIP-TABLE  is  a  keyword  that  disables  the 
source table download. This setting makes sense 
in  combination  with  a  manually  specified  mount 
point  as  the  source  table  download  and  an 
automatic  choice  of  a  suitable  reference  station 
is  needless  then.  This  parameter  is  reserved for 
GPRS connections. 

 

NEED-GGA  is  a  keyword  that  must  be  set  if  the 
reference  service  uses  the  VRS  concept  and 
therefore  requires  receiving  GGA  messages  in 
certain  time  intervals.  At  the  same  time  the 
come2ascos  is  controlled  by  GGA  messages:  If 
no GGA is received for 90 seconds the unit logs 
off until it receives a GGA message again. 

 

SKIP-NMEA  allows  disabling  the  GGA  control  for 
test  purpose.  The  device  connects  to  the 
reference  service  even  without  receiving  GGA 
messages.  Thus,  it  is  possible  to  test  the 
connection  to  the  reference  service  without 
connecting  a  GNSS  receiver  to  the  come2ascos 
device.  The  reference  service  will  neglect  the 
request  if  a  GGA  is  needed.  NEED-GGA  and 
SKIP-NMEA  cannot  be  set  at  the  same  time  as 
they are opposed to each other. 

Summary of Contents for COME2ASCOS

Page 1: ...QUICK REFERENCE COME2ASCOS UND COME2ASCOS BLUE ALLSAT GmbH Am Hohen Ufer 3A 30159 Hannover Germany Telefon 49 0 511 30 399 0 Telefax 49 0 511 30 399 66 Internet http www allsat de eMail info allsat de...

Page 2: ...QUICK REFERENCE COME2ASCOS AND COME2ASCOS BLUE 1 Last update 18 12 2008...

Page 3: ...iguration Software 7 Create configuration string manually 12 Configuration by SMS 15 Configuration by HyperTerminal 15 Configuration of the Bluetooth connection 16 Assembly come2ascos 18 Assembly come...

Page 4: ...on come2ascos is manufacturer independent and can be used as a correction data modem for different GNSS receivers You need a GSM card if necessary an additional GPRS tariff for operation As a supplier...

Page 5: ...the come2ascos device with stabilized power within a voltage range from 8 to 13 5 Voltage Start the configuration software and choose the serial interface at your Personal Computer Perform your indiv...

Page 6: ...SIM card again You will find the function for changing the PIN in the menu settings in many mobile phones Please note All saved SMS drafts on your SIM card will be deleted The come2ascos device saves...

Page 7: ...m via serial interface by SMS In the two last mentioned cases the configuration string has to be created manually You will find detailed information in the chapter Fehler Verweisquelle konnte nicht ge...

Page 8: ...our Personal Computer by the configuration cable Then proceed with the following steps Switch on the power supply The come2ascos device will register at the GSM net and indicate this state by a quickl...

Page 9: ...QUICK REFERENCE COME2ASCOS AND COME2ASCOS BLUE 8 figure 3...

Page 10: ...der is not listed it is explained below how you can add your individual entries to the pre defined settings CORRECTION DATA SETTINGS GPRS In this field the login details of your reference service prov...

Page 11: ...QUICK REFERENCE COME2ASCOS AND COME2ASCOS BLUE 10 figure 4...

Page 12: ...Configure Device The writing process needs several seconds while the come2ascos device should not be disconnected from power supply The button Read Settings from Device displays the current configurat...

Page 13: ...IFIER CONFIG MODEM BAUD_RATE MODUL MODULATION DIAL TEL_NUMMER OPTIONAL_PARAM Parameters semantics IDENTIFIER An identifier can be set as an optional parameter in order to distinguish between different...

Page 14: ...e Username and password are separated by colon MODULATION Unless a certain modulation type is not necessary for special applications use the standard setting autobauding For configuration use the keyw...

Page 15: ...d an automatic choice of a suitable reference station is needless then This parameter is reserved for GPRS connections NEED GGA is a keyword that must be set if the reference service uses the VRS conc...

Page 16: ...e configuration string is created like described in the chapter Create configuration string manually Additionally the string is exceeded by the Prefix PSLL and ends with a line feed CR NL Connect the...

Page 17: ...calls Thus every other active communication partner can built up a connection to the Bluetooth device For further setting options concerning the Bluetooth connection please take a look into the Free2m...

Page 18: ...QUICK REFERENCE COME2ASCOS AND COME2ASCOS BLUE 17 figure 6...

Page 19: ...ME2ASCOS BLUE 18 ASSEMBLY COME2ASCOS figure 7 Connect your come2ascos device as shown in figure 7 to power supply and your GNSS receiver by the split cable Don t forget connecting a GSM antenna GSM an...

Page 20: ...n module CHARGING Plug the connector of the battery charger into the charge socket beside the power switch Only use the battery charger delivered together with the come2ascos blue A full charge period...

Page 21: ...Ready off slowly flashing Send GGA message Connecting Pushbutton 2s Pause Mode Connecting quickly slowly flashing slowly flashing Please wait Authentication slowly flashing on Online authentication a...

Page 22: ...cos device starts connecting to the reference service This activity is indicated by the green LED The connecting procedure including the authentication lasts about one minute DATA TRANSMISSION Both LE...

Page 23: ...rs NTRIP LIST List of reference stations within the area of max 140 km GPRS STATUS GPRS gateway GPRS username GPRS password telephone provider received bytes transmitted bytes signal quality 3 is min...

Page 24: ...overage should be sufficient Best performance and stability is reached in areas with high signal quality If the coverage is not sufficient maybe another provider can offer a better net structure in yo...

Page 25: ...her Serial Port RS232 2400 57600 bauds 8 data bits 1 stop bit no parity POWER SUPPLY Voltage 7 5 15 5 VDC Supply current stand by 30mA 12VDC pause SMS 130mA 12VDC GPRS NTRIP 300mA 12VDC Peaks of curre...

Page 26: ...92 non condensing POWER SUPPLY Nominal voltage 6 VDC Accu capacity at least 2500mAh Operation time around 6 hours dependant on many different factors CONNECTOR The pin assignment of the 8 pin female...

Reviews: