background image

Page 5

ALLPRO Imaging

Knowledge of Warnings and Cautions.

Users must exercise every precaution to ensure personnel safety, and be familiar with the warnings and 
cautions presented throughout this manual and summarized below .  In this manual, the following 
definitions apply for all WARNING and CAUTION Statements:

WARNING:

  Any operation, procedure or practice, which, if not strictly observed, may result 

in injury or long-term health hazards to personnel.

CAUTION:

 Any operation, procedure or practice, which, if not strictly observed, may result 

in destruction of equipment or loss of effectiveness or damage to equipment 

and Phosphor Storage Plates (PSPs).

DANGER:

 

Opening ScanX by removing any covers or components makes the equipment 

into a Class III b Laser Product.  [Class 3B Laser Product (IEC 60825)].

Warnings -

Only trained professionals should use this device. 

Federal law prohibits the sale of this device to 

individuals other than trained professionals . Use of this device, other than as described in this 
manual, may result in injury .

ScanX contains a laser and is a Class 1 [Class 1 (IEC 60825)] Laser Product.

 

Use of controls or 

adjustments or performance of procedures other than those specified herein may result in hazardous 
radiation exposure . The laser is on only during an active scan .

Only a trained technician from an authorized dealer should remove a cover from the ScanX.

 

Direct eye 

contact with the output beam from the laser may cause serious damage and possible blindness .

Equipment Lifting.

  ScanX weighs up to 46 pounds and two people may be required to prevent injury 

when lifting .

Do not open the equipment to maintain it.  

ScanX contains no internal user serviceable parts . If there 

is a service problem, contact your authorized dealer .

Operate ScanX in dry environment. 

To prevent fire or electrical shock, do not expose this appliance to 

rain or moisture .

Equipment Disposal. 

Disposal of ScanX units, including internal batteries, electronic circuitry and PSPs 

must be accomplished only at the appropriate facilities for recovery and recycling . Make sure to 
dispose of such items in accordance with current federal, national, state and local government rules 
and regulations .

Cautions -

EMC Compliance Requirements.  

Use  USB cables not exceeding 10 feet (3m) to connect between 

the computer and the scanner .  Cable lengths greater than 10 feet may violate EMC compliance .
Stacking or using the scanner adjacent to other equipment may violate EMC compliance and interfere 
with the scanner operation .

Do not use damaged Phosphor Storage Plates (PSPs).

  Damaged PSPs may not provide reliable 

diagnostic images .

GENERAL SAFETY

Summary of Contents for ScanX trek D5000-T

Page 1: ...Operator s Manual Di g i tal Ima ging Sy s te m Part Numbers D5000 T and D5000 TB ScanX Trek without Battery D5000 T ScanX Trek with Battery D5000 TB...

Page 2: ......

Page 3: ...y listed below including devices with or without battery power Device Name Part No No Battery With Battery Trek D5000 T D5000 TB Designed and built exclusively for the demanding conditions encountered...

Page 4: ...y lead to a reduced level of safety of the resulting system Use of ACCESSORIES or cables other than those specified or provided by the manufacturer may result in increased EMISSIONS or decreased IMMUN...

Page 5: ...in hazardous radiation exposure The laser is on only during an active scan Only a trained technician from an authorized dealer should remove a cover from the ScanX Direct eye contact with the output...

Page 6: ...RE TO BEAM CLASS IIIb LASER PRODUCT COVER REMOVED MAKES THIS DEVICE A The ScanX is a Class I Laser Product Class 1 Laser Product IEC This warning label identifies the ScanX as such a product and descr...

Page 7: ...h regard to safety reliability and proper functioning only if assembly resetting changes or modifications and repairs have been carried out by an authorized dealer and if the equipment is used in conf...

Page 8: ...e received If any item is missing notify your dealer UNPACKING AND INSPECTION Figure 1 Typical ScanX Trek Product Family Packaging ScanX Unit Accessory Kit Accessory Kit Contents Accessory Literature...

Page 9: ...or for complete mobility inserted into either an optional hard or soft carrying case for easy and safe transport anywhere image scanning is required Rechargeable Battery The ScanX Trek has a model wi...

Page 10: ...midity 5 95 Non condensing Note Resolution of the ScanX is dependent on operating mode and specific imaging plate type used Resolution LP mm Horizontal Vertical 3 8 to 5 0 3 8 to 7 Compliance Data Las...

Page 11: ...x64 processor Microsoft Windows 7 Professional Enterprise or Ultimate with Service Pack 1 for an Intel 32 bit or an Intel 64 bit extended x64 processor Microsoft Windows 8 1 Professional or Enterprise...

Page 12: ...computer cm centimeter GB gigabyte 230 109 bytes GHz Gigahertz 109 of Hertz H height Hz Hertz cycles per second IEC International Electro technical Commission IMS Image Management Software IP imaging...

Page 13: ...t in the ON position depressed and flush with the panel this switch allows the ScanX to operate from battery power While engaged the CHARGE LEVEL Indicator illuminates 2 When placed in the OFF positio...

Page 14: ...ote When the Eraser Status Indicator displays a burst of approximately 5 quick flashes it is alerting the user that the erase function is reduced due to a high temperature condition in the red LED era...

Page 15: ...11 necessary to support ScanX operation Set up the computer according to the manufacturer s recommendations 2 Verify that an authorized Imaging Software and the supplied USB drivers are installed prop...

Page 16: ...e internal battery must always be charged prior to using To reach the full operational power level charge for at least 3 hours before using for the first time and on subsequent uses Refer to figure 6...

Page 17: ...with the plates CAUTION Use a Plate Protector for each plate PSPs may be exposed in cassettes and scanned without Plate Protectors however greater care must be exercised to not expose the PSP to light...

Page 18: ...ll be acquired Method 2 Perform the Activate Scanner and the Scanning and Erasing Plates procedures on pages 19 and 20 This method scans the plate and the imaging software may acquire a junk image sca...

Page 19: ...the ScanX The PSP is now ready to be scanned Activate Scanner Refer to Figure 9 and activate the ScanX via AC power or the internal Battery power by performing the fol lowing procedures 1 Refer to Fi...

Page 20: ...by both guide flaps resting on the inlet ring which further aids in alignment 5 At this point all four track lights will turn yellow indicating the PSP has been sensed and the Scanner is transporting...

Page 21: ...indicate that the Erase function is OFF The PSP will not be erased after scanning 4 Insert the PSP to be scanned into the ScanX by performing the Scanning and Erasing Plates procedures provided on the...

Page 22: ...not run Verify Computer System requirements Page 11 Make sure that the READY switch is set to ON and the green indicator is lit Reconnect the cable Check for tightness Replace if necessary Verify tha...

Page 23: ...long in cassette Partial image erasure due to exposure to light during han dling of the PSP Make sure the ScanX is operating with both eraser strips turned on blue LED indicator below the ERASER switc...

Page 24: ...no effect on the quality of the image and should be expected under normal conditions If the phosphor side is scratched make sure the plates are being handled properly and not being dragged from the Sc...

Page 25: ...pense the malfunctioning system back to ALLPRO Imaging in the same shipping container All equipment under warranty require a Return Materials Authorization RMA issued by Technical Services Items retur...

Page 26: ...ALLPRO Imaging Page 26 NOTES...

Page 27: ...Page 27 ALLPRO Imaging NOTES...

Page 28: ...and software to facilitate smooth and efficient radiography procedures Thousands of ALLPRO Imaging products have been sold globally installed and serviced through our network of authorized dealers Pr...

Reviews: