In general, it is recommended to disconnect your filter and 
clean the pipes, impeller and filter media monthly. 
Pipework will become blocked with waste and protein 
slime over time, so regular cleaning 

using a filter stem 

brush

 

is important for optimal performance. 

The frequency of how often you will need to clean and 
inspect your unit of course will depend on a lot of factors 
like how dirty the water is when you first start using your 
filter, the volume of your water and also how many fish you 
have. How often you feed your fish and how long your 
lighting is on for will also affect how quickly your aquarium 
water gets dirty and will need to be taken into 
consideration when planning how often to clean your filter. 

To clean the outside of the filter, you can periodically wipe 
with a damp cloth (use a cloth dampened with water from 
your aquarium, never use any chemical products or 
detergents). Lemon juice can also be used to removing 
any limescale build-up. Rinse thoroughly afterwards to 
remove any acidic residue.

Filter Maintenance

Sometimes delicate fish and plants require a gentler water 
flow. The filter's flow rate adjuster allows you to slow the 
flow of water whilst maintaining filtration efficiency. When 
the flow rate is decreased, up to 50% of water within the 
filter chamber is re-filtered several times, purifying the 
water further and creating a clean and clear aquarium.

It is also recommended to reduce the water flow rate 

during feeding. This results in greater food consumption 
and less waste.

Flow Rate Adjuster

Summary of Contents for 400-HO

Page 1: ...AQUARIUM HANG ON FILTER 400 HO 500 HO 600 HO...

Page 2: ......

Page 3: ...ections must be earthed The power cord of this appliance cannot be replaced if the cord is damaged the appliance should be discarded Never cut the cord Do not connect to any voltage other than that st...

Page 4: ...parts not intended to be wet The power cable must have a drop loop to avoid any condensation build up reaching the mains see diagram 1 If the plug does get wet DO NOT unplug the cord Disconnect the f...

Page 5: ...oving parts such as but not limited to heaters re ectors UV bulbs or impellers Please note this appliance can be used by children aged from 8 years and above and persons with reduced physical sensory...

Page 6: ...t any aspects of wiring INSTALLATION USE Please read the below instructions carefully before beginning to set up your lter DO NOT CONNECT THE UNIT TO THE MAINS UNTIL SET UP IS COMPLETE AND UNIT IS FIL...

Page 7: ...e e ciently To avoid priming problems ensure water level is high enough to submerge ALL inlet points and piping connections Switch on the unit Rotate the ow rate adjuster on the inlet pipe valve to in...

Page 8: ...OTOR BALANCE PLATE INLET PIPE PARTS DIAGRAM HO 500 FLOW RATE VALVE FILTER HOOD OUTLET MOTOR BALANCE PLATE INLET PIPE FLOW RATE VALVE FILTER HOOD SURFACE SKIMMER MOTOR LEFT BALANCE PLATE RIGHT BALANCE...

Page 9: ...lar cleaning of the lter media impeller inlet outlet pipework during a 10 25 water change will help ensure that the product works e ciently and the aquarium remains healthy For further maintenance gui...

Page 10: ...replace your impeller and ceramic shaft annually Switch o your lter at the mains and unplug the unit Pour out water from inside the HO lter Remove your HO lter from your aquarium Detach the motor fro...

Page 11: ...consideration when planning how often to clean your lter To clean the outside of the lter you can periodically wipe with a damp cloth use a cloth dampened with water from your aquarium never use any...

Page 12: ...to rinse your lter media is when doing a 10 20 water change as you can use this water to wash the media through When replacing media in your lter do not replace more than 50 of your media at once Thi...

Page 13: ...can take up to 3 weeks to successfully cycle You may also want to add a bacteria start treatment to your tank to speed up this process You may need to upgrade to a larger lter For reference you should...

Page 14: ...V bulbs are not covered by your warranty and a charge may be required for replacements of these This warranty does not apply to any unit that has been subjected to misuse accidental damage negligence...

Page 15: ......

Page 16: ......

Reviews: