22/24
6-1622420 rev. 1 21/12/2018
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
UP
DOWN
MENU
.
.
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
.
.
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
.
.
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
UP
DOWN
MENU
.
.
UP
DOWN
MENU
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
ENG
ITA
ENG
FRA
ESP
11 - SETTING OF THE STROKE - SINGLE MOTOR
Select the functioning with a single motor:
Make sure that the
board is out from any
programming menus
(press briefly the
“MENU” button).
To enter the menu,
press and hold the
“MENU” button for at
least 1 second.
Use the “UP” and
“DOWN” buttons to
move inside the items
of the menu.
Select the item
nmt
.
To enter the item,
press and hold the
“MENU” button for at
least 1 second until
the value blinks.
Use the “UP” and
“DOWN” buttons to
change the value.
To save the value,
press and hold the
“MENU” button for at
least 1 second.
To quit, press briefly
the “MENU” button.
WARNING - For a correct functioning of the system, it is absolutely indispensable the use of mechanical stops in opening and closing.
11.1 - EASY SETTINGS OF THE STROKE - SINGLE MOTOR
1.
Connect the automation to the MOTOR 1 output and check to have set
the
nMT
=
1
.
Carry out a check of the menus and, if needed, customize the settings before
the learning of the stroke.
The slowdowns will be those set in the menu, with the same percentage during
both opening and closing (
LSI
≠
P
).
2.
Unlock the automation and move it to the middle of the stroke.
Press at the same time the “UP“ and “MENU” buttons for at least 5 seconds
until the display shows
LOP
.
3.
If the automation DOESN’T MOVE in opening, press the “DOWN” button to stop
the learning. The display shows
L--
.
4.
Press the “SS” button to restart the procedure: the automation moves in
opening, at reduced speed.
Reached the opening mechanical stop, the motor stops automatically.
WARNING - if the motor doesn’t stop automatically, press the “SS”
button.
In this phase the display shows
LOP
.
5.
The automation moves automatically in closing, at running speed.
Reached the closing mechanical stop, the motor stops automatically.
WARNING - if the motor doesn’t stop automatically, press the “SS”
button.
In this phase the display shows
LCL
.
6.
The automation moves automatically in opening, at running speed.
Reached the opening mechanical stop, the motor stops automatically.
WARNING - if the motor doesn’t stop automatically, press the “SS”
button.
In this phase the display shows
LOP
.
7.
The automation moves in closing with the slowdowns set into the menu
LSI
.
5 seconds
Summary of Contents for BIOS2 24V
Page 1: ...MADE IN ITALY BIOS2 24V CENTRALINA PER CANCELLI A BATTENTE 24V...
Page 25: ...MADE IN ITALY BIOS2 24V CONTROL UNIT FOR WING GATES AT 24V...
Page 49: ...MADE IN ITALY BIOS2 24V CENTRAL DE COMMANDE POUR PORTAIL BATTANT 24V...
Page 73: ...MADE IN ITALY BIOS2 24V CUADRO DE MANDO PARA CANCELAS A HOJA 24V...