Non-Communicating
In non-communication applications this furnace is designed
to operate in a SINGLE-STAGE mode or TWO-STAGE mode
using a convention thermostat.
For optimal performance in non-communicating applications,
use a high quality electronic digital thermostat or any other
with adjustable settings for 1st stage / 2nd stage ON/OFF
differentials and adjustable stage timers.
Communicating
In communicating applications the Comfort Sync™
thermostat must be used. Refer to the instructions provided
with the thermostat for installation, set-up and operation. In
communicating systems all unused thermostat wire in the
wire bundle needs to be terminated inside and out. The
extra wires can terminate on the “C” terminal of the Comfort
Sync™ communication terminal strip. Using an additional
wire come off “C” terminal and wire nut all the extra wires
together. Termination on the outdoor control must match
the indoor control.
Indoor Blower Speeds
Non-Communicating
When the thermostat is set to “FAN ON”, the indoor blower
will run continuously at approximately 38% of the second
stage cooling speed when there is no cooling or heating
demand.
When the furnace is running in the heating mode, the indoor
blower will run on the heating speed designated by the
positions of DIP switches 11, 12 and 13.
When there is a cooling demand, the indoor blower will run
on the cooling speed designated by the positions of DIP
switches 5 and 6. First stage cooling will run at 70% cool
speed.
Communicating
NOTE:
When this furnace is used with a Comfort Sync™
thermostat, proper indoor blower speed selections are made
by the communicating thermostat.
When the thermostat is set to “FAN ON”, the indoor blower
will run at setting determined during system configuration.
When there is a heating demand the fan will run on heating
speeds for firing rate.
When there is a cooling demand, the fan will run on the first
stage and second stage cooling speed set using the Comfort
Sync™ thermostat in the installer setup mode. The factory
default is based upon 400 CFM per ton.
Summary of Contents for A96US2V
Page 3: ...507404 02 Page 3 of 80 Issue 1448 EXPANDED VIEW Figure 1 ...
Page 31: ...507404 02 Page 31 of 80 Issue 1448 Figure 38 ...
Page 38: ...507404 02 Page 38 of 80 Issue 1448 Figure 56 TRAP DRAIN ASSEMBLY USING 1 2 PVC or 3 4 PVC ...
Page 41: ...507404 02 Page 41 of 80 Issue 1448 Table 9 ...
Page 45: ...507404 02 Page 45 of 80 Issue 1448 ...
Page 47: ...507404 02 Page 47 of 80 Issue 1448 Integrated Control Figure 56 ...
Page 78: ...507404 02 Page 78 of 80 Issue 1448 Start Up Performance Check List UNIT SET UP ...
Page 79: ...507404 02 Page 79 of 80 Issue 1448 UNIT OPERATION Heating Mode Cooling Mode ...