Camera Link interface (O1-O4 or CL1, CL2)
Bonito Technical Manual
V2.2.1
34
Camera Link timing for dual channel mode (full line length, S=1,
not
for Bonito
CL-400B/C 200fps):
Camera Link timing for dual channel mode (compatibility mode with reduced
line length, S=3,
not
for Bonito CL-400B/C 200fps):
Figure 20: Timing dual channel, full line length
Figure 21: Timing dual channel, reduced line length