Installation
8
Table 1 provides an overview of the IEEE 802.3 specifications for network
configurations using thick, thin, and twisted-pair wiring.
Table 1: IEEE 802.3 Network Specifications
Location
Once you have installed the cables and placed the AT-810SL where you want
it, you can begin the actual connections.
The unit may be installed in any location where the LEDs will be visible for
monitoring and where there is adequate ventilation, temperature control and
power connections.
Desktop or rackmount installation is possible with ATI’s optional Rack Mount
Kit AT-RKMT5.
Power
AT-810SL requires a 100-120/200-240 VAC power source with a line frequency
of 50/60 Hz. The unit is equipped with an IEC-320/CEE-22 standard power
input connector on the back panel. One end of the power cord should have a
receptacle to fit this type of connector. The other end should be fitted with the
standard power cord plug for the country in which the unit will be operated.
A power cord is not provided for European AC outlets. Obtain the appropriate
cord from your equipment vendor.
10Base-T
10Base2
10Base5
Media
Twisted Pair
Cable
Thin Coaxial Cable
Thick Coaxial Cable
Topology
Star, Tree
Bus
Bus
External Devices
Network Adapter
Card
Network Adapter
Card
Network Adapter
Card and External
Transceiver
Maximum
Segment Length
100 meters
(328 ft.)
185 meters
(605 ft.)
457 meters
(1,500 ft.)
Maximum Devices
per Segment
12
30
100
Maximum Devices
per Network
1,024
1,024
1,024