Chapter 6: Building the Trunk with Default Stacking Ports 17 and 21
132
Starting a Local Management Session
This section contains the procedure for starting a local management
session on a stack. You can perform the procedure on any switch in a
stack. To start a local management session, perform the following
procedure:
1. Connect the RJ-45 connector on the management cable to the
Console port on the front panel of one of the switches in the stack. It
can be the master switch or a member switch. Refer to Figure 63.
Figure 63. Connecting the Management Cable to the Console Port
2. Connect the other end of the cable to an RS-232 port on a terminal or
computer with a terminal emulator program.
3. Configure the terminal or terminal emulator program as follows:
Baud rate: 9600 bps (The baud rate of the Console Port is
adjustable from 1200 to 115200 bps. The default is 9600 bps.)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.
4. Press Enter.