background image

AT-MCR1 Media Converter Chassis Installation Guide

25

Installing the Chassis On a Table or Desktop 

(AC Models Only)

To install the chassis on a table or desktop, perform the following 
procedure:

1.

Turn the AT-MCR1 chassis over.

2.

Attach the four protective rubber feet to the bottom of the 
chassis, as shown in Figure 7.

Figure 7. Attaching the Rubber Feet

3.

Turn the chassis over and place it on a flat and secure 
surface, leaving ample space around the chassis for 
ventilation.

The chassis is ready for cabling and powering up.

ˆ

For cabling instructions, refer to the installation guide that 
comes with the Allied Telesis media converter.

ˆ

For powering up instructions, refer to “Powering On an AC-
Powered Chassis” on page 34.

1051

PWR

1000Ba

s

e

AT-MC100

8

/GB  

GIG

AB

IT ETH

ER

NE

T M

ED

IA C

ON

VE

RTE

R   

                         

AUT

O M

DI/M

DI-

X

1000Ba

s

e-T

PWR

LINK

ACT

ML

S

ML

LT

MO

DE

LINK

ACT

CLASS 1

LASER PRODUCT

AT -M

CR

1

Summary of Contents for AT-MCR1

Page 1: ...Media Converter Chassis AT MCR1 Installation Guide 613 000687 Rev B...

Page 2: ...llied Telesis Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided herein is subject to chang...

Page 3: ...les These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if no...

Page 4: ...fety statement is available in a PDF document titled Translated Safety Statements posted on the Allied Telesis website at www alliedtelesis com Industry Canada This Class B digital apparatus meets all...

Page 5: ...ing Safety Precautions 16 Verifying the Package Contents 20 Selecting a Site 21 Installing a Media Converter in the Chassis 22 Installing the Chassis On a Table or Desktop AC Models Only 25 Installing...

Page 6: ...Contents 6 Temperature 45 Electrical Rating for AC version only 45 Safety and Electromagnetic Emissions Certifications 46 Compliance Standards 46...

Page 7: ...tructions on how to install an AT MCR1 Media Converter Chassis This preface contains the following sections Safety Symbols Used in this Document on page 8 Where to Find Web based Guides on page 9 Cont...

Page 8: ...uses the safety symbols in Table 1 Table 1 Safety Symbols Symbol Meaning Description Caution Performing or omitting a specific action may result in equipment damage or loss of data Warning Performing...

Page 9: ...Find Web based Guides The installation and user guides for all Allied Telesis products are available in portable document format PDF on our web site at www alliedtelesis com You can view the document...

Page 10: ...s com Select your country from the list displayed on the website then select the appropriate menu tab Warranty For hardware warranty information refer to the Allied Telesis web site www alliedtelesis...

Page 11: ...ation Guide 11 tab Sales or Corporate Information You can contact Allied Telesis for sales or corporate information on our web site www alliedtelesis com To find the contact information for your count...

Page 12: ...Preface 12...

Page 13: ...CR1 chassis provides convenient installation options on a desktop mounted under a table placed on the wall or installed in an industry standard 19 or 23 rack Figure 1 AT MCR1 Media Converter Chassis T...

Page 14: ...e slot for an ATI standard media converter Internal AC DC power supply Desktop wall under table or rack mount installation Status LEDs Refer to Table 2 for a description of the chassis LED Table 2 LED...

Page 15: ...edia Converter in the Chassis on page 22 Installing the Chassis On a Table or Desktop AC Models Only on page 25 Installing the Chassis Under a Table AC Models Only on page 26 Mounting the Chassis on t...

Page 16: ...er product L 1 Warning Do not work on equipment or cables during periods of lightning activity E2 Warning Power cord is used as a disconnection device To de energize equipment disconnect the power cor...

Page 17: ...and the DC power source Always connect the wires to the LAN equipment first before you connect the wires to the circuit breaker Do not work on HOT feeds to avoid the danger of physical injury from el...

Page 18: ...ied personnel are allowed to install or to replace this equipment E14 Caution The attached mounting brackets must be used to securely mount the device on the wall E15 Warning For centralized DC power...

Page 19: ...nstallation Guide 19 Warning Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch cir...

Page 20: ...ter Chassis with a mounting rail installed Four protective rubber feet for desktop use only Two mounting brackets Eight bracket mounting screws M3X6 Four wall mount plastic anchors No 6 10 7 8 inch Fo...

Page 21: ...openings on the unit Allow at least 10 centimeters 4 inches of space at the front and back of the unit for ventilation Make sure that the chassis power is accessible and cables can be connected easily...

Page 22: ...ove all components from the shipping packages Note Store the packaging material in a safe place You must use the original shipping material if you need to return the unit to Allied Telesis 2 Loosen th...

Page 23: ...rail against the media converter slide the two together into the chassis slot as shown in Figure 5 Figure 5 Sliding the Media Converter into the Chassis Slot 1000Base AT MC1008 GB GIG ABIT ETHERNET M...

Page 24: ...ptive screw on the mounting rail to secure the media converter in the chassis as shown in Figure 6 Figure 6 Tightening the Captive Screw on the Mounting Rail 1278 PWR 1000Base AT MC1008 G B GIGABIT ET...

Page 25: ...the Rubber Feet 3 Turn the chassis over and place it on a flat and secure surface leaving ample space around the chassis for ventilation The chassis is ready for cabling and powering up For cabling in...

Page 26: ...efore you install the AT MCR1 chassis under a table install the cables For cabling instructions refer to the installation guide that is shipped with the Allied Telesis media converter To install an AT...

Page 27: ...f the chassis under the table using the mounting screws not provided as shown in Figure 9 Figure 9 Mounting the Chassis under the Table 1052 PWR 1000Base AT M C1008 GB GIG ABIT ETHERNET MEDIA CONVERTE...

Page 28: ...Chapter 2 Installation 28 5 Make sure that the chassis is securely mounted under the table 6 Power the chassis on following the instructions in Powering On an AC Powered Chassis on page 34...

Page 29: ...mark two hole locations for the wall mounting screws or plastic wall anchors for wall mounting onto a concrete wall Note Make sure that the location provides easy access for installing the twisted pai...

Page 30: ...he mounting screws as shown in Figure 11 Figure 11 Mounting the Chassis on the Wall 1052 PWR 1000Base AT M C1008 GB GIG ABIT ETHERNET MEDIA CONVERTER AUTO MDI MDI X 1000Base T PWR LINK ACT ML SM L LT...

Page 31: ...the wall 6 Install the cables For cabling instructions refer to the installation guide that is shipped with the Allied Telesis media converter 7 Power on the chassis referring to one of the following...

Page 32: ...e mounting bracket provided to the right side of the AT MCR1 chassis using the bracket mounting screws provided as shown in Figure 12 Figure 12 Attaching Bracket for Rack Mounting Note Make sure that...

Page 33: ...ack 5 Install the cables For cabling instructions refer to the installation guide that is shipped with the Allied Telesis media converter 6 Power on the chassis referring to one of the following secti...

Page 34: ...rm the following procedure 1 Install the retaining clip on the chassis as shown in Figure 14 Figure 14 Installing the Power Cord Retaining Clip 2 Position the power cord retaining clip in the up posit...

Page 35: ...the Power Cord into the Chassis 4 Secure the cord by lowering the power cord retaining clip as shown in Figure 17 Figure 17 Securing the Power Cord with the Retaining Clip 5 Plug the other end of the...

Page 36: ...s runs a series of self diagnostic tests which take a few seconds to perform After the self tests are complete the chassis is ready for normal network operations For cabling instructions refer to the...

Page 37: ...ipment first before you connect the wiring to the circuit breaker Do not work with HOT feeds to avoid the danger of physical injury from electrical shock Always be sure that the breaker is in the OFF...

Page 38: ...e chassis is a DC terminal block starting from the left side of the terminal block identify the positive frame ground and negative terminals using the symbols above the terminal block as shown in Figu...

Page 39: ...frame ground wire to the terminal marked with the ground symbol by inserting the wire into the terminal and tightening the connection with a flathead screwdriver as shown in Figure 20 on page 39 Warni...

Page 40: ...connections being disturbed by casual contact with the wiring Use at least four cable ties separated four inches apart Locate the first one within six inches of the terminal block This system will wor...

Page 41: ...AT MCR1 Media Converter Chassis Installation Guide 41 For cabling instructions refer to the installation guide that is shipped with the Allied Telesis media converter...

Page 42: ...When you have finished installing the product register your product by completing the enclosed warranty card and sending it in You can also fill out the registration online by selecting Warranties un...

Page 43: ...o be sure that the power outlet has power by connecting another device to it Try replacing the power adapter with another power adapter If there is a communication problem between the end nodes connec...

Page 44: ...Chapter 3 Troubleshooting 44...

Page 45: ...Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 25 C to 70 C 13 F to 158 F Operating Humidity 5 to 90 non condensing Storage Humidity 5 to 95 non condensing Operating Altitude Up t...

Page 46: ...dix A Technical Specifications 46 Safety and Electromagnetic Emissions Certifications RFI Emissions FCC Part 15 Class B Immunity EN55024 Electrical Safety EN60950 TUV CE Compliance Standards RoHS Comp...

Reviews: