C613-50066-01 REV A
Command Reference for IE200 Series Industrial Managed PoE+ Switches
305
AlliedWare Plus™ Operating System - Version 5.4.5I-0.x
A
LARM
M
ONITORING
C
OMMANDS
ALARM
FACILITY
Default
All alarms are disabled by default.
Mode
Global Configuration
Usage
Enabling alarms allows you to monitor the switch environment and respond to
problems as they occur.
Example
To turn on the LED in case a loop occurs, use the command:
awplus#
configure terminal
awplus(config)#
alarm facility looprot led
To have an alarm when the contact input is open, use the command:
awplus#
configure terminal
awplus(config)#
alarm facility input-alarm 1 alarm-position
open
To turn off the led from flashing when the device temperature is too high, use the
command:
awplus#
configure terminal
awplus(config)#
no alarm facility temperature led
main-pse
Main power source equipment failure alarm. The sum
of the power consumed by all of the PoE devices
plugged into the switch exceeds the maximum
permitted.
Note: This alarm pertains to PoE models only.
power-supply
Power supply failure alarm. The designated power
supply is down.
<power-supply-number>
The power supply unit number. The switch has two
power supplies, so the number must be 1 or 2.
pse-port
PoE failure on a switch port alarm. A PoE device
plugged into a port is consuming more than the
maximum power output for the port.
temperature
High temperature alarm. If enabled, this alarm is
triggered when the temperature of the device
exceeds 95 degrees Celsius.
led
Enable or disable the LED for the alarm.
relay
Enable or disable the relay output for the alarm.
alarm-position
The position (open or closed) of the input contact
corresponding to the alarm that has occurred.
open
The electrical circuit for the contact input is open.
close
The electrical circuit for the contact input is closed.
Parameter
Description