53
Chapter 3
Troubleshooting
Follow the guidelines below to test and troubleshoot the installation in the
event a problem occurs.
If the PWR LED is OFF, do the following:
If the bridging converter is installed on a desktop, check to be sure
that the power adapter is securely connected to a power outlet and
that the power adapter cable is securely connected to the back of the
converter.
Verify that the power outlet has power by connecting another device
to it.
Try using another power adapter.
If the LINK LED for the twisted pair port is OFF, do the following:
Check that the end-node connected to the port is powered ON and is
operating properly.
Check that the twisted pair cable is securely connected to the twisted
pair port on the bridging converter and on the end-node.
Check to be sure that the end-node connected to the AT-GS2002
Series converter is operating at the same duplex mode or that both
the AT-GS2002 and the end-node are both configured for Auto-
Negotiation.
Make sure that the twisted pair cable does not exceed 100 meters
(328 feet) and that you are using a Category 5 or better cable.